Assessment Year 2000
Principal Product Printed Advertising
NAICS
n/a
SIC 2752: Commercial Printing, Lithographic
Sales Range $10
M
to 50
M
# of Employees 400
Plant Area
n/a
Annual Production 75,000,000
pieces
Production Hrs. Annual 7,344
hrs
Location (State) Texas

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $177,088 4,787,808
kWh
Electricity Demand $78,900 11,799
kW-mo/yr
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $30,282 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $1,468

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings
01 2.3212: Optimize plant power factor $15,795 $15,500 - $15,795
-
kW-mo/yr
02 2.7135: Install occupancy sensors $9,378 $2,709 $9,378
302,462
kWh
-
03 2.7144: Install spectral reflectors / delamp $937 $1,725 - $937
-
kW-mo/yr
04 2.7124: Make a practice of turning off lights when not needed $2,704 - $1,720
55,393
kWh
$984
-
kW-mo/yr
05 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $1,375 $900 $1,000
32,239
kWh
$375
-
kW-mo/yr
06 2.7142: Utilize higher efficiency lamps and/or ballasts $93 $461 $71
2,345
kWh
$22
-
kW-mo/yr
TOTAL RECOMMENDED $30,282 $21,295 $12,169
392,439
kWh
$18,113
-
kW-mo/yr
TOTAL IMPLEMENTED $1,468 $1,361 $1,071
34,584
kWh
$397
-
kW-mo/yr
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs