Assessment Year | 2000 |
---|---|
Principal Product | Printed Advertising |
NAICS |
n/a
|
SIC | 2752: Commercial Printing, Lithographic |
Sales Range | $10 M to 50M |
# of Employees | 400 |
Plant Area |
n/a
|
Annual Production | 75,000,000
pieces
|
Production Hrs. Annual | 7,344
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $177,088 | 4,787,808 |
kWh
|
$0.037 |
Electricity Demand | $78,900 | 11,799 |
kW-mo/yr
|
$6.69 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $30,282 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $1,468 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.3212: Optimize plant power factor | $15,795 | $15,500 | - |
$15,795
-
kW-mo/yr
|
|
02 | 2.7135: Install occupancy sensors | $9,378 | $2,709 |
$9,378
302,462
kWh
|
- | |
03 | 2.7144: Install spectral reflectors / delamp | $937 | $1,725 | - |
$937
-
kW-mo/yr
|
|
04 | 2.7124: Make a practice of turning off lights when not needed | $2,704 | - |
$1,720
55,393
kWh
|
$984
-
kW-mo/yr
|
|
05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,375 | $900 |
$1,000
32,239
kWh
|
$375
-
kW-mo/yr
|
|
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $93 | $461 |
$71
2,345
kWh
|
$22
-
kW-mo/yr
|
|
TOTAL RECOMMENDED | $30,282 | $21,295 |
$12,169
392,439
kWh
|
$18,113
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | $1,468 | $1,361 |
$1,071
34,584
kWh
|
$397
-
kW-mo/yr
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs