Assessment Year | 1993 |
---|---|
Principal Product | App. Timers and Auto Switches |
NAICS |
n/a
|
SIC | 3822: Automatic Controls for Regulating Residential and Commercial Environments and Appliances |
Sales Range | $50 M to 100M |
# of Employees | 494 |
Plant Area |
n/a
|
Annual Production | 17,000,000
pieces
|
Production Hrs. Annual | 7,488
hrs
|
Location (State) | Indiana |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $425,273 | 9,368,699 |
kWh
|
$0.045 |
Natural Gas | $65,710 | 18,635 |
MMBtu
|
$3.53 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $85,008 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.7232: Replace existing hvac unit with high efficiency model | $62,950 | $259,500 | n/a |
$62,950
522,274
kWh
|
- |
02 | 2.3212: Optimize plant power factor | $6,581 | $14,600 | n/a |
$6,581
-
kWh
|
- |
03 | 2.4133: Use most efficient type of electric motors | $5,783 | $22,950 | n/a |
$5,783
127,491
kWh
|
- |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,617 | $910 | n/a |
$2,617
58,910
kWh
|
- |
05 | 2.7135: Install occupancy sensors | $1,587 | $600 | n/a |
$1,587
34,877
kWh
|
- |
06 | 2.4221: Install compressor air intakes in coolest locations | $1,507 | $500 | n/a |
$1,507
33,118
kWh
|
- |
07 | 2.7447: Install vinyl strip / high speed / air curtain doors | $1,437 | $1,140 | n/a | - |
$1,437
-
MMBtu
|
08 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,052 | - | n/a |
$1,052
23,154
kWh
|
- |
09 | 2.7111: Reduce illumination to minimum necessary levels | $680 | $300 | n/a |
$680
14,947
kWh
|
- |
10 | 2.6218: Turn off equipment when not in use | $677 | - | n/a |
$677
14,947
kWh
|
- |
11 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $137 | $150 | n/a |
$137
2,931
kWh
|
- |
TOTAL RECOMMENDED | $85,008 | $300,650 |
$83,571
832,649
kWh
|
$1,437
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs