ITAC Assessment: ND0175
ITAC logo
ITAC Assessment: ND0175
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1993
Principal Product App. Timers and Auto Switches
NAICS
n/a
SIC 3822: Automatic Controls for Regulating Residential and Commercial Environments and Appliances
Sales Range $50
M
to 100
M
# of Employees 494
Plant Area
n/a
Annual Production 17,000,000
pieces
Production Hrs. Annual 7,488
hrs
Location (State) Indiana

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $425,273 9,368,699
kWh
Natural Gas $65,710 18,635
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $85,008 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings
01 2.7232: Replace existing hvac unit with high efficiency model $62,950 $259,500 n/a $62,950
522,274
kWh
-
02 2.3212: Optimize plant power factor $6,581 $14,600 n/a $6,581
-
kWh
-
03 2.4133: Use most efficient type of electric motors $5,783 $22,950 n/a $5,783
127,491
kWh
-
04 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $2,617 $910 n/a $2,617
58,910
kWh
-
05 2.7135: Install occupancy sensors $1,587 $600 n/a $1,587
34,877
kWh
-
06 2.4221: Install compressor air intakes in coolest locations $1,507 $500 n/a $1,507
33,118
kWh
-
07 2.7447: Install vinyl strip / high speed / air curtain doors $1,437 $1,140 n/a - $1,437
-
MMBtu
08 2.4111: Utilize energy-efficient belts and other improved mechanisms $1,052 - n/a $1,052
23,154
kWh
-
09 2.7111: Reduce illumination to minimum necessary levels $680 $300 n/a $680
14,947
kWh
-
10 2.6218: Turn off equipment when not in use $677 - n/a $677
14,947
kWh
-
11 2.7142: Utilize higher efficiency lamps and/or ballasts $137 $150 n/a $137
2,931
kWh
-
TOTAL RECOMMENDED $85,008 $300,650 $83,571
832,649
kWh
$1,437
-
MMBtu
TOTAL IMPLEMENTED - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs