Assessment Year 1995
Principal Product Printed circuit boards
NAICS
n/a
SIC 3672: Printed Circuit Boards
Sales Range $10
M
to 50
M
# of Employees 400
Plant Area 90,000
ft2
Annual Production 1,000,000
pieces
Production Hrs. Annual 6,240
hrs
Location (State) Florida

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $505,138 7,483,294
kWh
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $69,740 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $65,686

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Administrative Changes Savings
01 2.8123: Pay utility bills on time $2,000 - - $2,000
02 2.7142: Utilize higher efficiency lamps and/or ballasts $7,338 $1,066 $7,338
118,699
kWh
-
03 2.7142: Utilize higher efficiency lamps and/or ballasts $11,718 $25,077 $11,718
182,884
kWh
-
04 2.7135: Install occupancy sensors $3,323 $532 $3,323
62,720
kWh
-
05 2.7142: Utilize higher efficiency lamps and/or ballasts $731 $1,160 $731
9,672
kWh
-
06 2.7232: Replace existing hvac unit with high efficiency model $39,531 $14,650 $39,531
515,533
kWh
-
07 2.4133: Use most efficient type of electric motors $1,903 $3,716 $1,903
28,722
kWh
-
08 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $3,196 $850 $3,196
46,893
kWh
-
TOTAL RECOMMENDED $69,740 $47,051 $67,740
965,123
kWh
$2,000
TOTAL IMPLEMENTED $65,686 $45,359 $63,686
892,731
kWh
$2,000
Yearly Savings* Imp'd Cost* Electricity Usage Savings Administrative Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs