Assessment Year | 1993 |
---|---|
Principal Product | Kitchen and Camping Utensils |
NAICS |
n/a
|
SIC | 3469: Metal Stampings, Not Elsewhere Classified |
Sales Range | $1 M to 5M |
# of Employees | 17 |
Plant Area |
59,000
ft2
|
Annual Production | 75,000,000
pieces
|
Production Hrs. Annual | 2,210
hrs
|
Location (State) | Indiana |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $26,147 | 216,295 |
kWh
|
$0.12 |
Natural Gas | $15,320 | 3,018 |
MMBtu
|
$5.08 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $12,048 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.7447: Install vinyl strip / high speed / air curtain doors | $4,917 | $1,821 | n/a | - |
$4,917
-
MMBtu
|
- |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,686 | $200 | n/a |
$2,686
27,550
kWh
|
- | - |
03 | 2.4133: Use most efficient type of electric motors | $656 | $1,220 | n/a |
$656
6,155
kWh
|
- | - |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,118 | $225 | n/a |
$1,118
11,430
kWh
|
- | - |
05 | 2.8123: Pay utility bills on time | $1,136 | - | n/a | - | - | $1,136 |
06 | 2.4221: Install compressor air intakes in coolest locations | $539 | $1,000 | n/a |
$539
5,569
kWh
|
- | - |
07 | 2.7243: Improve air circulation with destratification fans / other methods | $415 | $800 | n/a | - |
$415
-
MMBtu
|
- |
08 | 2.7111: Reduce illumination to minimum necessary levels | $260 | - | n/a |
$260
2,638
kWh
|
- | - |
09 | 2.7447: Install vinyl strip / high speed / air curtain doors | $221 | $553 | n/a | - |
$221
-
MMBtu
|
- |
10 | 2.7447: Install vinyl strip / high speed / air curtain doors | $100 | $382 | n/a | - |
$100
-
MMBtu
|
- |
TOTAL RECOMMENDED | $12,048 | $6,201 |
$5,259
53,342
kWh
|
$5,653
-
MMBtu
|
$1,136 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs