Assessment Year | 1991 |
---|---|
Principal Product | VAN CONVERSIONS |
NAICS |
n/a
|
SIC | 3716: Motor Homes |
Sales Range | $50 M to 100M |
# of Employees | 600 |
Plant Area |
n/a
|
Annual Production | 10,000
pieces
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | Indiana |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $429,195 | 5,424,092 |
kWh
|
$0.079 |
Natural Gas | $22,584 | 4,950 |
MMBtu
|
$4.56 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $65,603 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.7111: Reduce illumination to minimum necessary levels | $22,384 | $500 |
$22,384
290,152
kWh
|
- | |
02 | 2.7494: Install storm windows and doors | $12,542 | $7,950 | - |
$12,542
-
MMBtu
|
|
03 | 2.8121: Apply for tax-free status for energy purchases | $21,460 | $250 |
$21,460
-
kWh
|
- | |
04 | 2.4133: Use most efficient type of electric motors | $1,289 | $2,835 |
$1,289
16,706
kWh
|
- | |
05 | 2.4221: Install compressor air intakes in coolest locations | $3,865 | $1,600 |
$3,865
49,531
kWh
|
- | |
06 | 2.7122: Disconnect ballasts | $954 | $500 |
$954
12,309
kWh
|
- | |
07 | 2.6232: Install set-back timers | $3,109 | $1,100 |
$3,109
40,445
kWh
|
- | |
TOTAL RECOMMENDED | $65,603 | $14,735 |
$53,061
409,143
kWh
|
$12,542
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs