Assessment Year | 2018 |
---|---|
Principal Product | Mirrors and glass |
NAICS | 327215: Glass Product Manufacturing Made of Purchased Glass |
SIC | 3231: Glass Products, Made of Purchased Glass |
Sales Range | $50 M to 100M |
# of Employees | 130 |
Plant Area |
165,000
ft2
|
Annual Production | 1,000,000
pieces
|
Production Hrs. Annual | 4,800
hrs
|
Location (State) | North Carolina |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $224,243 | 3,150,173 |
kWh
|
$0.071 |
Electricity Demand | $53,260 | 12,275 |
kW-mo/yr
|
$4.34 |
Natural Gas | $24,847 | 2,863 |
MMBtu
|
$8.68 |
TOTAL YEARLY COSTS | $302,350 | |||
RECOMMENDED SAVINGS* | $205,171 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $169,797 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Ancillary Material Cost Savings | Primary Product Savings | Increase in Production Savings |
---|---|---|---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $13,771 | $43,490 |
$11,715
164,533
kWh
|
$2,056
-
kW-mo/yr
|
- | - | - | - | - | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,695 | $225 |
$1,659
23,302
kWh
|
$261
-
kW-mo/yr
|
- | $(-180.0) | $(-45.0) | - | - | |
03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $505 | $50 |
$435
6,114
kWh
|
$70
-
kW-mo/yr
|
- | - | - | - | - | |
04 | 2.4226: Use / purchase optimum sized compressor | $12,380 | $20,000 |
$10,701
150,298
kWh
|
$1,679
-
kW-mo/yr
|
- | - | - | - | - | |
05 | 2.4226: Use / purchase optimum sized compressor | $1,999 | $100 |
$1,999
28,080
kWh
|
- | - | - | - | - | - | |
06 | 2.5194: Redesign process | $7,804 | $10,000 | - | - |
$304
-
MMBtu
|
- | - | $7,500 | - | |
07 | 4.126: Install sensors to detect defects | $112,500 | $150,000 | - | - | - | - | - | - | $112,500 | |
08 | 2.5194: Redesign process | $36,741 | $2,500 |
$(-656.0)
(-9,216)
kWh
|
$(-103.0)
-
kW-mo/yr
|
- | - | - | $37,500 | - | |
09 | 2.4154: Avoid rewinding motors more than twice | $2,586 | $5,865 |
$2,236
31,406
kWh
|
$350
-
kW-mo/yr
|
- | - | - | - | - | |
10 | 2.8114: Change rate schedules or other changes in utility service | $15,190 | $500 |
$15,190
-
kWh
|
- | - | - | - | - | - | |
TOTAL RECOMMENDED | $205,171 | $232,730 |
$43,279
394,517
kWh
|
$4,313
-
kW-mo/yr
|
$304
-
MMBtu
|
$(-180.0) | $(-45.0) | $45,000 | $112,500 | ||
TOTAL IMPLEMENTED | $169,797 | $202,230 |
$17,388
244,219
kWh
|
$2,634
-
kW-mo/yr
|
- | $(-180.0) | $(-45.0) | $37,500 | $112,500 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Ancillary Material Cost Savings | Primary Product Savings | Increase in Production Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs