Assessment Year 2016
Principal Product Aluminum extrusions
NAICS 331318: Other Aluminum Rolling, Drawing, and Extruding
SIC 3354: Aluminum Extruded Products
Sales Range $10
M
to 50
M
# of Employees 100
Plant Area 195,000
ft2
Annual Production 30,000,000
lb
Production Hrs. Annual 7,200
hrs
Location (State) North Carolina

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $631,150 8,188,064
kWh
Natural Gas $116,596 39,716
MMBtu
TOTAL YEARLY COSTS $747,746
RECOMMENDED SAVINGS* $42,259 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $22,065

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Personnel Changes Savings Ancillary Material Cost Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $11,828 $21,764 $10,418
135,289
kWh
- $1,410
02 2.7142: Utilize higher efficiency lamps and/or ballasts $9,293 $35,726 $7,782
101,070
kWh
- $1,511
03 2.7134: Use photocell controls $2,850 $150 $2,850
37,011
kWh
- -
04 2.7142: Utilize higher efficiency lamps and/or ballasts $2,443 $12,240 $2,169
28,172
kWh
- $274
05 2.7135: Install occupancy sensors $307 $571 $307
3,986
kWh
- -
06 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $944 $200 $1,294
16,800
kWh
$(-150.0) $(-200.0)
07 2.4226: Use / purchase optimum sized compressor $11,387 $100 $11,387
147,887
kWh
- -
08 2.4239: Eliminate or reduce compressed air usage $117 $180 $117
1,522
kWh
- -
09 2.4151: Develop a repair/replace policy $2,418 $5,865 $2,418
31,406
kWh
- -
10 2.4111: Utilize energy-efficient belts and other improved mechanisms $672 $103 $672
8,718
kWh
- -
TOTAL RECOMMENDED $42,259 $76,899 $39,414
511,861
kWh
$(-150.0) $2,995
TOTAL IMPLEMENTED $22,065 $57,690 $19,494
253,159
kWh
$(-150.0) $2,721
Yearly Savings* Imp'd Cost* Electricity Usage Savings Personnel Changes Savings Ancillary Material Cost Savings