Assessment Year | 2016 |
---|---|
Principal Product | Furniture frames |
NAICS | 337121: Upholstered Household Furniture Manufacturing |
SIC | 2512: Wood Household Furniture, Upholstered |
Sales Range | $10 M to 50M |
# of Employees | 122 |
Plant Area |
258,933
ft2
|
Annual Production | 140,000
pieces
|
Production Hrs. Annual | 7,500
hrs
|
Location (State) | North Carolina |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $319,018 | 5,454,090 |
kWh
|
$0.058 |
Electricity Demand | $48,071 | 10,752 |
kW-mo/yr
|
$4.47 |
Wood | $21,080 | 7,492 |
MMBtu
|
$2.81 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $82,847 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $68,617 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.4226: Use / purchase optimum sized compressor | $13,092 | $8,000 |
$13,092
223,800
kWh
|
- | - | - | |
02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $2,608 | $100 |
$2,314
39,555
kWh
|
$294
-
kW-mo/yr
|
- | - | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,361 | $200 |
$1,694
28,954
kWh
|
$207
-
kW-mo/yr
|
$(-300.0) | $(-240.0) | |
04 | 2.4239: Eliminate or reduce compressed air usage | $552 | $1,500 |
$474
8,100
kWh
|
$78
-
kW-mo/yr
|
- | - | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $48,868 | $143,752 |
$42,208
721,503
kWh
|
$6,660
-
kW-mo/yr
|
- | - | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $9,769 | $32,929 |
$7,148
122,180
kWh
|
$2,621
-
kW-mo/yr
|
- | - | |
07 | 2.7135: Install occupancy sensors | $1,138 | $1,215 |
$1,138
19,456
kWh
|
- | - | - | |
08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $863 | $300 |
$375
6,412
kWh
|
$39
-
kW-mo/yr
|
- | $449 | |
09 | 2.6218: Turn off equipment when not in use | $2,806 | $4,000 |
$2,806
47,962
kWh
|
- | - | - | |
10 | 2.4151: Develop a repair/replace policy | $977 | $4,256 |
$707
12,089
kWh
|
$270
-
kW-mo/yr
|
- | - | |
11 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $813 | $281 |
$589
10,062
kWh
|
$224
-
kW-mo/yr
|
- | - | |
TOTAL RECOMMENDED | $82,847 | $196,533 |
$72,545
1,240,073
kWh
|
$10,393
-
kW-mo/yr
|
$(-300.0) | $209 | ||
TOTAL IMPLEMENTED | $68,617 | $187,318 |
$58,315
996,817
kWh
|
$10,393
-
kW-mo/yr
|
$(-300.0) | $209 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs