Assessment Year | 2015 |
---|---|
Principal Product | Cardboard retail displays |
NAICS | 322230: Stationery Product Manufacturing |
SIC | 2675: Die-Cut Paper and Paperboard and Cardboard |
Sales Range | $10 M to 50M |
# of Employees | 65 |
Plant Area |
100,000
ft2
|
Annual Production | 77,000
thousand feet
|
Production Hrs. Annual | 2,250
hrs
|
Location (State) | North Carolina |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $69,990 | 1,078,656 |
kWh
|
$0.065 |
Electricity Demand | $22,755 | 6,897 |
kW-mo/yr
|
$3.30 |
Natural Gas | $6,333 | 893 |
MMBtu
|
$7.09 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $34,843 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $700 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Ancillary Material Cost Savings | Increase in Production Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 4.625: Develop standard operating procedures | $27,300 | $10,000 | - | - | - | - | - | $27,300 | |
02 | 2.7111: Reduce illumination to minimum necessary levels | $2,334 | $1,131 |
$1,692
26,064
kWh
|
$458
-
kW-mo/yr
|
- | - | $184 | - | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $596 | $160 |
$277
4,275
kWh
|
$20
-
kW-mo/yr
|
- | - | $299 | - | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $299 | $405 |
$213
3,281
kWh
|
$58
-
kW-mo/yr
|
- | - | $28 | - | |
05 | 2.7135: Install occupancy sensors | $536 | $918 |
$536
8,267
kWh
|
- | - | - | - | - | |
06 | 2.7313: Recycle air for heating, ventilation and air conditioning | $1,054 | $5,000 | - | - |
$1,054
-
MMBtu
|
- | - | - | |
07 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $634 | $3,000 |
$499
7,695
kWh
|
$135
-
kW-mo/yr
|
- | - | - | - | |
08 | 2.2437: Recover waste heat from equipment | $627 | $470 | - | - |
$627
-
MMBtu
|
- | - | - | |
09 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $104 | $100 |
$176
2,719
kWh
|
$48
-
kW-mo/yr
|
- | $(-100.0) | $(-20.0) | - | |
10 | 2.4239: Eliminate or reduce compressed air usage | $116 | $240 |
$116
1,784
kWh
|
- | - | - | - | - | |
11 | 2.4151: Develop a repair/replace policy | $935 | $4,256 |
$736
11,333
kWh
|
$199
-
kW-mo/yr
|
- | - | - | - | |
12 | 2.7261: Install timers and/or thermostats | $308 | $600 |
$308
4,741
kWh
|
- | - | - | - | - | |
TOTAL RECOMMENDED | $34,843 | $26,280 |
$4,553
70,159
kWh
|
$918
-
kW-mo/yr
|
$1,681
-
MMBtu
|
$(-100.0) | $491 | $27,300 | ||
TOTAL IMPLEMENTED | $700 | $260 |
$453
6,994
kWh
|
$68
-
kW-mo/yr
|
- | $(-100.0) | $279 | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Ancillary Material Cost Savings | Increase in Production Savings |