Assessment Year 2014
Principal Product Automotive bearing
NAICS 336310: Motor Vehicle Gasoline Engine and Engine Parts Manufacturing
SIC 3562: Ball and Roller Bearings
Sales Range $50
M
to 100
M
# of Employees 600
Plant Area 216,000
ft2
Annual Production 150,000,000
pieces
Production Hrs. Annual 7,250
hrs
Location (State) Virginia

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $1,082,604 33,998,400
kWh
Electricity Demand $1,292,758 62,573
kW-mo/yr
Electricity Fees $3,480 -
Natural Gas $196,736 32,275
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $105,257 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $101,427

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Personnel Changes Savings Administrative Changes Savings Ancillary Material Cost Savings
01 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $17,220 $200 $9,288
281,451
kWh
$11,132
-
kW-mo/yr
$(-1,600.0) - $(-1,600.0)
02 2.4224: Upgrade controls on compressors $80,544 $28,000 $36,632
1,110,048
kWh
$43,912
-
kW-mo/yr
- - -
03 2.7142: Utilize higher efficiency lamps and/or ballasts $836 $240 $212
6,412
kWh
$175
-
kW-mo/yr
- - $449
04 2.7142: Utilize higher efficiency lamps and/or ballasts $874 $1,255 $253
7,675
kWh
$598
-
kW-mo/yr
- $23 -
05 2.3132: Recharge batteries on during off-peak demand periods $625 $100 - $625
-
kW-mo/yr
- - -
06 2.4111: Utilize energy-efficient belts and other improved mechanisms $2,956 $1,935 $1,339
40,571
kWh
$1,617
-
kW-mo/yr
- - -
07 2.4151: Develop a repair/replace policy $2,202 $4,256 $1,006
30,221
kWh
$1,196
-
kW-mo/yr
- - -
TOTAL RECOMMENDED $105,257 $35,986 $48,730
1,476,378
kWh
$59,255
-
kW-mo/yr
$(-1,600.0) $23 $(-1,151.0)
TOTAL IMPLEMENTED $101,427 $32,796 $47,138
1,428,132
kWh
$57,040
-
kW-mo/yr
$(-1,600.0) - $(-1,151.0)
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Personnel Changes Savings Administrative Changes Savings Ancillary Material Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs