| Assessment Year | 2009 |
|---|---|
| Principal Product | Blow molded plastic parts |
| NAICS | 326199: All Other Plastics Product Manufacturing |
| SIC | 3089: Plastics Products, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 135 |
| Plant Area |
80,000
ft2
|
| Annual Production | 1,000,000
pieces
|
| Production Hrs. Annual | 8,600
hrs
|
| Location (State) | North Carolina |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $284,932 | 9,139,780 |
kWh
|
$0.031 |
| Electricity Demand | $142,834 | 17,763 |
kW-mo/yr
|
$8.04 |
| Electricity Fees | $6,915 | - |
|
- |
| Natural Gas | $31,252 | 2,274 |
MMBtu
|
$13.74 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $16,917 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $12,048 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.4226: Use / purchase optimum sized compressor | $4,869 | $25,000 |
$3,640
110,990
kWh
|
$1,229
-
kW-mo/yr
|
- | - | - | |
| 02 | 2.1233: Analyze flue gas for proper air/fuel ratio | $400 | $10,000 | - | - |
$400
-
MMBtu
|
- | - | |
| 03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,091 | $100 |
$1,264
38,528
kWh
|
$427
-
kW-mo/yr
|
- | $(-300.0) | $(-300.0) | |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,810 | - |
$3,161
96,382
kWh
|
$1,327
-
kW-mo/yr
|
- | $(-1,032.0) | $354 | |
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $99 | $150 |
$74
2,248
kWh
|
$25
-
kW-mo/yr
|
- | - | - | |
| 06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $995 | $160 |
$99
3,008
kWh
|
$72
-
kW-mo/yr
|
- | $619 | $205 | |
| 07 | 2.4151: Develop a repair/replace policy | $5,653 | $8,935 |
$4,226
128,834
kWh
|
$1,427
-
kW-mo/yr
|
- | - | - | |
| TOTAL RECOMMENDED | $16,917 | $44,345 |
$12,464
379,990
kWh
|
$4,507
-
kW-mo/yr
|
$400
-
MMBtu
|
$(-713.0) | $259 | ||
| TOTAL IMPLEMENTED | $12,048 | $19,345 |
$8,824
269,000
kWh
|
$3,278
-
kW-mo/yr
|
$400
-
MMBtu
|
$(-713.0) | $259 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Ancillary Material Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs