Assessment Year 2007
Principal Product Furniture
NAICS 337122: Nonupholstered Wood Household Furniture Manufacturing
SIC 2511: Wood Household Furniture, Except Upholstered
Sales Range $100
M
to 500
M
# of Employees 1,000
Plant Area 300,000
ft2
Annual Production 350,000
pieces
Production Hrs. Annual 4,000
hrs
Location (State) North Carolina

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $843,283 18,703,101
kWh
Electricity Demand $167,366 48,512
kW-mo/yr
Coal $57,622 13,230
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $62,769 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $11,812

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Coal Savings Water Disposal Savings Personnel Changes Savings Ancillary Material Cost Savings
01 2.3414: Burn waste to produce steam to drive a steam turbine generator set and use steam exhaust for heat $42,586 $100,000 $46,150
923,735
kWh
$8,169
-
kW-mo/yr
- $(-8,733.0)
-
Tgal
- $(-3,000.0)
02 2.4151: Develop a repair/replace policy $640 $1,297 $530
10,605
kWh
$110
-
kW-mo/yr
- - - -
03 2.2437: Recover waste heat from equipment $4,202 $7,000 - - $4,202
-
MMBtu
- - -
04 2.4221: Install compressor air intakes in coolest locations $2,775 $5,800 $2,360
47,240
kWh
$415
-
kW-mo/yr
- - - -
05 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $8,986 $100 $9,395
188,055
kWh
$1,191
-
kW-mo/yr
- - $(-1,200.0) $(-400.0)
06 2.4239: Eliminate or reduce compressed air usage $267 $960 $224
4,477
kWh
$43
-
kW-mo/yr
- - - -
07 2.7142: Utilize higher efficiency lamps and/or ballasts $1,394 $3,917 $1,087
21,751
kWh
$307
-
kW-mo/yr
- - - -
08 2.7142: Utilize higher efficiency lamps and/or ballasts $1,919 $50 $1,535
30,720
kWh
$384
-
kW-mo/yr
- - - -
TOTAL RECOMMENDED $62,769 $119,124 $61,281
1,226,583
kWh
$10,619
-
kW-mo/yr
$4,202
-
MMBtu
$(-8,733.0)
-
Tgal
$(-1,200.0) $(-3,400.0)
TOTAL IMPLEMENTED $11,812 $2,407 $11,684
233,857
kWh
$1,728
-
kW-mo/yr
- - $(-1,200.0) $(-400.0)
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Coal Savings Water Disposal Savings Personnel Changes Savings Ancillary Material Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs