Assessment Year | 2007 |
---|---|
Principal Product | Furniture |
NAICS | 337122: Nonupholstered Wood Household Furniture Manufacturing |
SIC | 2511: Wood Household Furniture, Except Upholstered |
Sales Range | $100 M to 500M |
# of Employees | 1,000 |
Plant Area |
300,000
ft2
|
Annual Production | 375,000
pieces
|
Production Hrs. Annual | 4,000
hrs
|
Location (State) | Virginia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $429,879 | 14,258,000 |
kWh
|
$0.030 |
Electricity Demand | $363,960 | 43,277 |
kW-mo/yr
|
$8.41 |
Electricity Fees | $22,198 | - |
|
- |
Coal | $91,490 | 21,609 |
MMBtu
|
$4.23 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $86,167 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $6,887 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Coal Savings | Water Disposal Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.3413: Burn fossil fuel to produce steam to drive a steam turbine-generator and use steam exhaust for heat | $43,971 | $100,000 |
$29,834
989,520
kWh
|
$25,613
-
kW-mo/yr
|
$(-3,077.0)
-
MMBtu
|
$(-8,399.0)
-
Tgal
|
- | - | |
02 | 2.3321: Use steam pressure reduction to generate power | $9,176 | $30,000 |
$8,206
272,160
kWh
|
$3,310
-
kW-mo/yr
|
$(-1,340.0)
-
MMBtu
|
- | - | $(-1,000.0) | |
03 | 2.4151: Develop a repair/replace policy | $588 | $1,297 |
$320
10,605
kWh
|
$268
-
kW-mo/yr
|
- | - | - | - | |
04 | 2.2437: Recover waste heat from equipment | $4,742 | $6,500 | - | - |
$4,742
-
MMBtu
|
- | - | - | |
05 | 2.4221: Install compressor air intakes in coolest locations | $2,263 | $5,800 |
$1,252
41,515
kWh
|
$1,011
-
kW-mo/yr
|
- | - | - | - | |
06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,600 | $100 |
$3,945
130,960
kWh
|
$1,655
-
kW-mo/yr
|
- | - | $(-1,200.0) | $(-800.0) | |
07 | 2.4239: Eliminate or reduce compressed air usage | $389 | $960 |
$172
5,720
kWh
|
$217
-
kW-mo/yr
|
- | - | - | - | |
08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $17,438 | $76,397 |
$13,533
448,872
kWh
|
$7,551
-
kW-mo/yr
|
- | - | - | $(-3,646.0) | |
09 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,310 | $50 |
$1,030
34,160
kWh
|
$1,280
-
kW-mo/yr
|
- | - | - | - | |
10 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,690 | $5,576 |
$671
22,269
kWh
|
$1,019
-
kW-mo/yr
|
- | - | - | - | |
TOTAL RECOMMENDED | $86,167 | $226,680 |
$58,963
1,955,781
kWh
|
$41,924
-
kW-mo/yr
|
$325
-
MMBtu
|
$(-8,399.0)
-
Tgal
|
$(-1,200.0) | $(-5,446.0) | ||
TOTAL IMPLEMENTED | $6,887 | $2,407 |
$5,467
181,445
kWh
|
$3,420
-
kW-mo/yr
|
- | - | $(-1,200.0) | $(-800.0) | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Coal Savings | Water Disposal Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs