Assessment Year | 2005 |
---|---|
Principal Product | Upholstered chairs |
NAICS | 337121: Upholstered Household Furniture Manufacturing |
SIC | 2512: Wood Household Furniture, Upholstered |
Sales Range | $5 M to 10M |
# of Employees | 40 |
Plant Area |
50,000
ft2
|
Annual Production | 10,000
pieces
|
Production Hrs. Annual | 2,500
hrs
|
Location (State) | North Carolina |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $24,605 | 441,960 |
kWh
|
$0.056 |
Electricity Demand | $11,139 | 2,621 |
kW-mo/yr
|
$4.25 |
Natural Gas | $13,924 | 1,427 |
MMBtu
|
$9.76 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $9,784 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $8,187 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.4226: Use / purchase optimum sized compressor | $3,743 | $100 |
$2,673
55,000
kWh
|
$1,070
-
kW-mo/yr
|
- | - | - | - | |
02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $595 | $200 |
$425
8,750
kWh
|
$170
-
kW-mo/yr
|
- | - | - | - | |
03 | 2.2437: Recover waste heat from equipment | $410 | $820 | - | - |
$410
-
MMBtu
|
- | - | - | |
04 | 2.4151: Develop a repair/replace policy | $56 | $83 |
$38
780
kWh
|
$18
-
kW-mo/yr
|
- | - | - | - | |
05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $71 | $38 |
$51
1,050
kWh
|
$20
-
kW-mo/yr
|
- | - | - | - | |
06 | 2.7313: Recycle air for heating, ventilation and air conditioning | $1,266 | $2,312 |
$1,560
32,100
kWh
|
$625
-
kW-mo/yr
|
$2,206
-
MMBtu
|
- | $(-3,125.0) | - | |
07 | 3.5313: Increase amount of waste recovered for resale | $2,000 | $1,000 | - | - | - |
$2,000
-
lb
|
- | - | |
08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $661 | - |
$472
9,707
kWh
|
$189
-
kW-mo/yr
|
- | - | - | - | |
09 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $331 | $300 |
$95
1,950
kWh
|
$38
-
kW-mo/yr
|
- | - | $167 | $31 | |
10 | 2.7229: Air condition only space necessary | $651 | $1,251 |
$369
7,586
kWh
|
$282
-
kW-mo/yr
|
- | - | - | - | |
TOTAL RECOMMENDED | $9,784 | $6,104 |
$5,683
116,923
kWh
|
$2,412
-
kW-mo/yr
|
$2,616
-
MMBtu
|
$2,000
-
lb
|
$(-2,958.0) | $31 | ||
TOTAL IMPLEMENTED | $8,187 | $3,492 |
$4,028
82,873
kWh
|
$1,749
-
kW-mo/yr
|
$410
-
MMBtu
|
$2,000
-
lb
|
- | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs