| Assessment Year | 2003 |
|---|---|
| Principal Product | Roasted In-shell Peanuts |
| NAICS | 326111: Plastics Bag and Pouch Manufacturing |
| SIC | 2068: Salted and Roasted Nuts and Seeds |
| Sales Range | $10 M to 50M |
| # of Employees | 75 |
| Plant Area |
42,500
ft2
|
| Annual Production | 35,000,000
lb
|
| Production Hrs. Annual | 6,000
hrs
|
| Location (State) | North Carolina |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $46,046 | 1,309,170 |
kWh
|
$0.035 |
| Electricity Demand | $32,116 | 2,986 |
kW-mo/yr
|
$10.76 |
| Electricity Fees | $3,229 | - |
|
- |
| LPG | $249,945 | 40,134 |
MMBtu
|
$6.23 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $49,427 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | LPG Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.7135: Install occupancy sensors | $396 | $208 |
$218
6,192
kWh
|
$178
-
kW-mo/yr
|
- | |
| 02 | 2.2443: Re-use or recycle hot or cold process exhaust air | $19,437 | $8,000 | - | - |
$19,437
-
MMBtu
|
|
| 03 | 2.2443: Re-use or recycle hot or cold process exhaust air | $16,074 | $9,000 | - | - |
$16,074
-
MMBtu
|
|
| 04 | 2.1122: Re-size charging openings or add a movable door on equipment | $606 | $176 | - | - |
$606
-
MMBtu
|
|
| 05 | 2.7313: Recycle air for heating, ventilation and air conditioning | $11,263 | $16,548 | - | - |
$11,263
-
MMBtu
|
|
| 06 | 2.7124: Make a practice of turning off lights when not needed | $234 | - |
$234
6,645
kWh
|
- | - | |
| 07 | 2.4151: Develop a repair/replace policy | $347 | $260 |
$215
6,125
kWh
|
$132
-
kW-mo/yr
|
- | |
| 08 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $264 | $252 |
$164
4,652
kWh
|
$100
-
kW-mo/yr
|
- | |
| 09 | 2.7134: Use photocell controls | $806 | $550 |
$328
9,330
kWh
|
$478
-
kW-mo/yr
|
- | |
| TOTAL RECOMMENDED | $49,427 | $34,994 |
$1,159
32,944
kWh
|
$888
-
kW-mo/yr
|
$47,380
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | LPG Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs