Assessment Year 2003
Principal Product Roasted In-shell Peanuts
NAICS 326111: Plastics Bag and Pouch Manufacturing
SIC 2068: Salted and Roasted Nuts and Seeds
Sales Range $10
M
to 50
M
# of Employees 75
Plant Area 42,500
ft2
Annual Production 35,000,000
lb
Production Hrs. Annual 6,000
hrs
Location (State) North Carolina

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $46,046 1,309,170
kWh
Electricity Demand $32,116 2,986
kW-mo/yr
Electricity Fees $3,229 -
LPG $249,945 40,134
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $49,427 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings LPG Savings
01 2.7135: Install occupancy sensors $396 $208 $218
6,192
kWh
$178
-
kW-mo/yr
-
02 2.2443: Re-use or recycle hot or cold process exhaust air $19,437 $8,000 - - $19,437
-
MMBtu
03 2.2443: Re-use or recycle hot or cold process exhaust air $16,074 $9,000 - - $16,074
-
MMBtu
04 2.1122: Re-size charging openings or add a movable door on equipment $606 $176 - - $606
-
MMBtu
05 2.7313: Recycle air for heating, ventilation and air conditioning $11,263 $16,548 - - $11,263
-
MMBtu
06 2.7124: Make a practice of turning off lights when not needed $234 - $234
6,645
kWh
- -
07 2.4151: Develop a repair/replace policy $347 $260 $215
6,125
kWh
$132
-
kW-mo/yr
-
08 2.4111: Utilize energy-efficient belts and other improved mechanisms $264 $252 $164
4,652
kWh
$100
-
kW-mo/yr
-
09 2.7134: Use photocell controls $806 $550 $328
9,330
kWh
$478
-
kW-mo/yr
-
TOTAL RECOMMENDED $49,427 $34,994 $1,159
32,944
kWh
$888
-
kW-mo/yr
$47,380
-
MMBtu
TOTAL IMPLEMENTED - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings LPG Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs