Assessment Year | 1998 |
---|---|
Principal Product | hand held electric power tools |
NAICS |
n/a
|
SIC | 3546: Power-Driven Handtools |
Sales Range | $10 M to 50M |
# of Employees | 320 |
Plant Area |
124,880
ft2
|
Annual Production | 50,000,000
pieces
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | North Carolina |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $285,255 | 7,926,143 |
kWh
|
$0.036 |
Electricity Demand | $207,157 | 18,414 |
kW-mo/yr
|
$11.25 |
Electricity Fees | $1,071 | - |
|
- |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $21,102 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $12,408 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | Other Liquid (haz) Savings | Solid Waste (non-haz) Savings | Primary Raw Material Savings |
---|---|---|---|---|---|---|---|---|---|---|---|
01 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $3,673 | $14,934 |
$2,880
80,012
kWh
|
$2,700
-
kW-mo/yr
|
$(-1,907.0)
-
MMBtu
|
- | - | - | - | |
02 | 2.6231: Utilize controls to operate equipment only when needed | $2,664 | $1,000 |
$2,664
74,150
kWh
|
- | - | - | - | - | - | |
03 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $2,696 | $12,000 |
$1,120
31,067
kWh
|
$2,799
-
kW-mo/yr
|
$(-1,223.0)
-
MMBtu
|
- | - | - | - | |
04 | 2.4226: Use / purchase optimum sized compressor | $2,617 | $4,731 |
$2,617
72,685
kWh
|
- | - | - | - | - | - | |
05 | 3.5313: Increase amount of waste recovered for resale | $113 | $200 | - | - | - | - | - |
$113
-
lb
|
- | |
06 | 3.4155: Meter waste water | $1,464 | $200 | - | - | - |
$1,464
-
Tgal
|
- | - | - | |
07 | 3.2123: Convert to high volume low pressure (hvlp) paint guns | $5,550 | $2,700 | - | - | - | - | - | - | $5,550 | |
08 | 3.3131: Use evaporation to concentrate material | $2,325 | $12,000 | - | - |
$(-225.0)
-
MMBtu
|
- |
$2,550
-
gal
|
- | - | |
TOTAL RECOMMENDED | $21,102 | $47,765 |
$9,281
257,914
kWh
|
$5,499
-
kW-mo/yr
|
$(-3,355.0)
-
MMBtu
|
$1,464
-
Tgal
|
$2,550
-
gal
|
$113
-
lb
|
$5,550 | ||
TOTAL IMPLEMENTED | $12,408 | $8,831 |
$5,281
146,835
kWh
|
- | - |
$1,464
-
Tgal
|
- |
$113
-
lb
|
$5,550 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | Other Liquid (haz) Savings | Solid Waste (non-haz) Savings | Primary Raw Material Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs