Assessment Year | 1995 |
---|---|
Principal Product | Corrugated Boxes |
NAICS |
n/a
|
SIC | 2653: Corrugated and Solid Fiber Boxes |
Sales Range | $10 M to 50M |
# of Employees | 136 |
Plant Area |
231,000
ft2
|
Annual Production | 6,000,000
lb
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | North Carolina |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $309,190 | 5,580,305 |
kWh
|
$0.055 |
Natural Gas | $181,661 | 43,283 |
MMBtu
|
$4.20 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $51,499 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $19,123 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Solid Waste (non-haz) Savings |
---|---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,790 | $360 |
$1,790
44,256
kWh
|
- | - | |
02 | 2.4133: Use most efficient type of electric motors | $1,315 | $1,122 |
$1,315
26,671
kWh
|
- | - | |
03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $3,692 | $919 |
$3,692
74,736
kWh
|
- | - | |
04 | 2.4221: Install compressor air intakes in coolest locations | $618 | $680 |
$618
11,430
kWh
|
- | - | |
05 | 2.7447: Install vinyl strip / high speed / air curtain doors | $9,392 | $45,000 |
$(-397.0)
(-6,741)
kWh
|
$9,789
-
MMBtu
|
- | |
06 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $1,162 | - |
$1,162
-
kWh
|
- | - | |
07 | 2.7314: Reduce ventilation air | $21,249 | $25,000 | - |
$21,249
-
MMBtu
|
- | |
08 | 2.7491: Insulate glazing, walls, ceilings, and roofs | $9,347 | $34,448 | - |
$9,347
-
MMBtu
|
- | |
09 | 2.1233: Analyze flue gas for proper air/fuel ratio | $2,713 | $600 | - |
$2,713
-
MMBtu
|
- | |
10 | 3.5316: Contract a wood pallet recycling company | $200 | $100 | - | - |
$200
-
lb
|
|
11 | 3.5313: Increase amount of waste recovered for resale | $21 | $100 | - | - |
$21
-
lb
|
|
TOTAL RECOMMENDED | $51,499 | $108,329 |
$8,180
150,352
kWh
|
$43,098
-
MMBtu
|
$221
-
lb
|
||
TOTAL IMPLEMENTED | $19,123 | $48,201 |
$6,400
138,922
kWh
|
$12,502
-
MMBtu
|
$221
-
lb
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Solid Waste (non-haz) Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs