ITAC Assessment: NC0039
ITAC logo
ITAC Assessment: NC0039
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1994
Principal Product Fire Protection Valves and Meters
NAICS
n/a
SIC 3494: Valves and Pipe Fittings, Not Elsewhere Classified
Sales Range $10
M
to 50
M
# of Employees 163
Plant Area 141,000
ft2
Annual Production 0
units
Production Hrs. Annual 6,000
hrs
Location (State) North Carolina

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $208,248 4,126,026
kWh
Natural Gas $43,254 7,972
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $51,392 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $13,169

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $4,241 $2,018 $4,241
84,994
kWh
-
02 2.1311: Replace electrically-operated equipment with fossil fuel equipment $3,052 $3,850 - $3,052
-
MMBtu
03 2.2614: Use cooling tower or economizer to replace chiller cooling $1,432 $1,500 $1,432
26,084
kWh
-
04 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $3,710 $600 $3,710
74,150
kWh
-
05 2.4221: Install compressor air intakes in coolest locations $1,600 $420 $1,600
38,101
kWh
-
06 2.2437: Recover waste heat from equipment $5,307 $2,500 - $5,307
-
MMBtu
07 2.4133: Use most efficient type of electric motors $2,306 $5,070 $2,306
42,790
kWh
-
08 2.4111: Utilize energy-efficient belts and other improved mechanisms $156 $570 $156
2,931
kWh
-
09 2.3137: Use power during off-peak periods $8,928 - $8,928
-
kWh
-
10 2.7243: Improve air circulation with destratification fans / other methods $18,760 $16,000 - $18,760
-
MMBtu
11 2.7444: Close holes and openings in building such as broken windows $1,900 $500 - $1,900
-
MMBtu
TOTAL RECOMMENDED $51,392 $33,028 $22,373
269,050
kWh
$29,019
-
MMBtu
TOTAL IMPLEMENTED $13,169 $2,018 $13,169
84,994
kWh
-
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs