| Assessment Year | 2026 |
|---|---|
| Principal Product | aircraft maintenance |
| NAICS | 336411: Aircraft Manufacturing |
| SIC | 3721: Aircraft |
| Sales Range | $100 M to 500M |
| # of Employees | 1,062 |
| Plant Area |
1,300,000
ft2
|
| Annual Production | 615
pieces
|
| Production Hrs. Annual | 8,760
hrs
|
| Location (State) | Kansas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $640,309 | 17,013,318 |
kWh
|
$0.038 | |
| Electricity Demand | $878,880 | 37,626 |
kW-mo/yr
|
$23.36 | |
| Natural Gas | $377,698 | 62,842 |
MMBtu
|
$6.01 | |
| Waste Disposal Costs | |||||
| Water Usage | $123,448 | 5,648 |
Tgal
|
$21.86 | |
| TOTAL YEARLY COSTS | $2,020,335 | ||||
| RECOMMENDED SAVINGS* | $1,427,959 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | - | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $41,275 | $43,520 |
$41,275
1,086,189
kWh
|
- | - | - | |
| 02 | 2.2625: Chill water to the highest temperature possible | $39,211 | $44,974 |
$14,608
384,430
kWh
|
$24,603
-
kW-mo/yr
|
- | - | |
| 03 | 2.2622: Replace existing chiller with high efficiency model | $45,369 | $248,235 |
$16,902
444,797
kWh
|
$28,467
-
kW-mo/yr
|
- | - | |
| 04 | 2.4221: Install compressor air intakes in coolest locations | $2,750 | $8,700 |
$1,494
39,237
kWh
|
$1,256
-
kW-mo/yr
|
- | - | |
| 05 | 2.2449: Recover heat from exhausted steam, hot air or hot water | $6,611 | $16,100 | - | - |
$6,611
-
MMBtu
|
- | |
| 06 | 2.9121: Install wind powered electric generator | $1,273,555 | $6,683,350 |
$432,595
11,384,082
kWh
|
$840,960
-
kW-mo/yr
|
- | - | |
| 07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $17,369 | $47,422 |
$2,525
66,550
kWh
|
$6,626
-
kW-mo/yr
|
- | $8,218 | |
| 08 | 2.7135: Install occupancy sensors | $1,060 | $7,800 |
$1,060
27,886
kWh
|
- | - | - | |
| 09 | 2.7111: Reduce illumination to minimum necessary levels | $759 | $1,500 |
$61
1,622
kWh
|
$218
-
kW-mo/yr
|
- | $480 | |
| TOTAL RECOMMENDED | $1,427,959 | $7,101,601 |
$510,520
13,434,793
kWh
|
$902,130
-
kW-mo/yr
|
$6,611
-
MMBtu
|
$8,698 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs