Assessment Year | 2021 |
---|---|
Principal Product | Plastic roof vents |
NAICS | 326199: All Other Plastics Product Manufacturing |
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 154 |
Plant Area |
140,000
ft2
|
Annual Production | 23,000,000
lb
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Missouri |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $469,256 | 6,898,400 |
kWh
|
$0.068 | |
Electricity Demand | $126,211 | 16,676 |
kW-mo/yr
|
$7.57 | |
Waste Disposal Costs | |||||
Water Usage | $13,265 | 1,263 |
Tgal
|
$10.50 | |
Water Disposal | $8,594 | 1,263 |
Tgal
|
$6.81 | |
TOTAL YEARLY COSTS | $617,326 | ||||
RECOMMENDED SAVINGS* | $117,109 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | $117,109 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Water Disposal Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $35,170 | $360 |
$30,931
409,269
kWh
|
$4,239
-
kW-mo/yr
|
- | - | |
02 | 2.4221: Install compressor air intakes in coolest locations | $1,308 | $6,600 |
$1,135
16,689
kWh
|
$173
-
kW-mo/yr
|
- | - | |
03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $3,695 | $19,524 |
$3,695
54,340
kWh
|
- | - | - | |
04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $4,814 | $320 |
$4,177
61,435
kWh
|
$637
-
kW-mo/yr
|
- | - | |
05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $363 | $60 |
$315
4,637
kWh
|
$48
-
kW-mo/yr
|
- | - | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $24,474 | $14,349 |
$18,840
277,056
kWh
|
$3,361
-
kW-mo/yr
|
- | $2,273 | |
07 | 3.4116: Meter recycled water (to reduce sewer charges) | $3,124 | $4,744 | - | - |
$3,124
-
Tgal
|
- | |
08 | 2.7447: Install vinyl strip / high speed / air curtain doors | $2,022 | $5,800 |
$1,542
22,698
kWh
|
$480
-
kW-mo/yr
|
- | - | |
09 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $42,139 | $30,100 |
$42,139
619,685
kWh
|
- | - | - | |
TOTAL RECOMMENDED | $117,109 | $81,857 |
$102,774
1,465,809
kWh
|
$8,938
-
kW-mo/yr
|
$3,124
-
Tgal
|
$2,273 | ||
TOTAL IMPLEMENTED | $117,109 | $81,857 |
$102,774
1,465,809
kWh
|
$8,938
-
kW-mo/yr
|
$3,124
-
Tgal
|
$2,273 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Water Disposal Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs