Assessment Year | 2017 |
---|---|
Principal Product | Steel Joists |
NAICS | 332312: Fabricated Structural Metal Manufacturing |
SIC | 3441: Fabricated Structural Metal |
Sales Range | $10 M to 50M |
# of Employees | 135 |
Plant Area |
112,107
ft2
|
Annual Production | 30,000
units
|
Production Hrs. Annual | 4,125
hrs
|
Location (State) | Missouri |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $221,629 | 3,044,400 |
kWh
|
$0.073 | |
Electricity Demand | $25,224 | 9,286 |
kW-mo/yr
|
$2.72 | |
Natural Gas | $76,204 | 11,090 |
MMBtu
|
$6.87 | |
Waste Disposal Costs | |||||
Water Usage | $2,296 | 435,369 |
Tgal
|
$0.005 | |
TOTAL YEARLY COSTS | $325,353 | ||||
RECOMMENDED SAVINGS* | $36,873 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | $30,666 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.7447: Install vinyl strip / high speed / air curtain doors | $19,149 | $22,600 |
$(-138.9)
(-1,902)
kWh
|
- |
$19,288
-
MMBtu
|
|
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $525 | $50 |
$473
6,482
kWh
|
$52
-
kW-mo/yr
|
- | |
03 | 2.4221: Install compressor air intakes in coolest locations | $1,852 | $1,250 |
$1,671
22,892
kWh
|
$181
-
kW-mo/yr
|
- | |
04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $2,463 | $2,250 |
$2,222
30,443
kWh
|
$241
-
kW-mo/yr
|
- | |
05 | 2.2437: Recover waste heat from equipment | $1,752 | $550 | - | - |
$1,752
-
MMBtu
|
|
06 | 2.4322: Use or replace with energy efficient substitutes | $4,716 | $5,600 |
$4,255
58,288
kWh
|
$461
-
kW-mo/yr
|
- | |
07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,904 | $15,775 |
$3,405
46,649
kWh
|
$499
-
kW-mo/yr
|
- | |
08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,021 | $4,675 |
$913
12,512
kWh
|
$108
-
kW-mo/yr
|
- | |
09 | 2.7135: Install occupancy sensors | $1,491 | $760 |
$1,491
20,419
kWh
|
- | - | |
TOTAL RECOMMENDED | $36,873 | $53,510 |
$14,291
195,783
kWh
|
$1,542
-
kW-mo/yr
|
$21,040
-
MMBtu
|
||
TOTAL IMPLEMENTED | $30,666 | $47,150 |
$8,545
117,076
kWh
|
$1,081
-
kW-mo/yr
|
$21,040
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs