Assessment Year | 2017 |
---|---|
Principal Product | automotive axles and drive shafts |
NAICS | 336211: Motor Vehicle Body Manufacturing |
SIC | 3714: Motor Vehicle Parts and Accessories |
Sales Range | $100 M to 500M |
# of Employees | 100 |
Plant Area |
136,000
ft2
|
Annual Production | 352,000
pieces
|
Production Hrs. Annual | 4,000
hrs
|
Location (State) | Missouri |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $363,144 | 3,344,365 |
kWh
|
$0.11 | |
Electricity Demand | $76,470 | 8,707 |
kW-mo/yr
|
$8.78 | |
Natural Gas | $32,729 | 4,551 |
MMBtu
|
$7.19 | |
Waste Disposal Costs | |||||
Water Usage | $4,861 | 486,075 |
Tgal
|
$0.010 | |
TOTAL YEARLY COSTS | $477,204 | ||||
RECOMMENDED SAVINGS* | $24,135 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | $24,135 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.4221: Install compressor air intakes in coolest locations | $10,101 | $1,160 |
$8,655
79,400
kWh
|
$1,446
-
kW-mo/yr
|
- | |
02 | 2.7221: Lower temperature during the winter season and vice-versa | $4,200 | - |
$4,200
38,535
kWh
|
- | - | |
03 | 2.7447: Install vinyl strip / high speed / air curtain doors | $6,574 | $100 |
$4,913
45,072
kWh
|
- |
$1,661
-
MMBtu
|
|
04 | 2.7135: Install occupancy sensors | $1,286 | $2,350 |
$1,286
11,796
kWh
|
- | - | |
05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,974 | - |
$1,974
18,112
kWh
|
- | - | |
TOTAL RECOMMENDED | $24,135 | $3,610 |
$21,028
192,915
kWh
|
$1,446
-
kW-mo/yr
|
$1,661
-
MMBtu
|
||
TOTAL IMPLEMENTED | $24,135 | $3,610 |
$21,028
192,915
kWh
|
$1,446
-
kW-mo/yr
|
$1,661
-
MMBtu
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs