Assessment Year | 2010 |
---|---|
Principal Product | bottled soft drink |
NAICS | 312111: Soft Drink Manufacturing |
SIC | 2086: Bottled and Canned Soft Drinks and Carbonated Waters |
Sales Range | $10 M to 50M |
# of Employees | 36 |
Plant Area |
243,000
ft2
|
Annual Production | 180
Tgal
|
Production Hrs. Annual | 7,000
hrs
|
Location (State) | Missouri |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $174,762 | 5,980,800 |
kWh
|
$0.029 |
Electricity Demand | $70,772 | 14,327 |
kW-mo/yr
|
$4.94 |
Natural Gas | $143,896 | 29,729 |
MMBtu
|
$4.84 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $105,244 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $105,244 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.1224: Replace boiler | $33,880 | $115,000 | - | - |
$33,880
-
MMBtu
|
|
02 | 2.7492: Use proper thickness of insulation on building envelope | $959 | $1,000 | - | - |
$959
-
MMBtu
|
|
03 | 2.2437: Recover waste heat from equipment | $22,455 | $10,000 | - | - |
$22,455
-
MMBtu
|
|
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $18,022 | $33,660 |
$14,877
362,866
kWh
|
$3,145
-
kW-mo/yr
|
- | |
05 | 2.7135: Install occupancy sensors | $888 | $1,550 |
$888
21,672
kWh
|
- | - | |
06 | 2.6218: Turn off equipment when not in use | $987 | - |
$987
24,080
kWh
|
- | - | |
07 | 2.4221: Install compressor air intakes in coolest locations | $3,342 | $1,160 |
$2,770
67,568
kWh
|
$572
-
kW-mo/yr
|
- | |
08 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $4,601 | - |
$4,601
112,227
kWh
|
- | - | |
09 | 2.4231: Reduce the pressure of compressed air to the minimum required | $2,207 | - |
$2,207
53,837
kWh
|
- | - | |
10 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,916 | $1,100 |
$2,916
71,132
kWh
|
- | - | |
11 | 2.6231: Utilize controls to operate equipment only when needed | $14,987 | $5,000 |
$14,987
365,540
kWh
|
- | - | |
TOTAL RECOMMENDED | $105,244 | $168,470 |
$44,233
1,078,922
kWh
|
$3,717
-
kW-mo/yr
|
$57,294
-
MMBtu
|
||
TOTAL IMPLEMENTED | $105,244 | $168,470 |
$44,233
1,078,922
kWh
|
$3,717
-
kW-mo/yr
|
$57,294
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs