Assessment Year 2025
Principal Product beer and canned beverages
NAICS 424810: Beer and Ale Merchant Wholesalers
SIC 5181: Beer and Ale
Sales Range $100
M
to 500
M
# of Employees 180
Plant Area 165,000
ft2
Annual Production 5,200,000
units
Production Hrs. Annual 2,080
hrs
Location (State) Michigan

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $70,818 1,149,845
kWh
Electricity Demand $55,602 3,202
kW-mo/yr
Electricity Fees $47,761 -
Natural Gas $66,628 9,964
MMBtu
Other Gas $5,689 1
MMBtu
TOTAL YEARLY COSTS $246,497
RECOMMENDED SAVINGS* $29,688 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings
01 2.7226: Use computer programs to optimize hvac performance $11,904 $500 $2,954
47,639
kWh
$2,683
-
kW-mo/yr
- $6,267
-
MMBtu
02 2.7447: Install vinyl strip / high speed / air curtain doors $5,412 $17,495 $796
12,838
kWh
$(-1,456.8)
-
kW-mo/yr
- $6,073
-
MMBtu
03 2.2136: Install / repair insulation on steam lines $393 $457 $284
4,608
kWh
$110
-
kW-mo/yr
- -
04 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $17 - $7
106
kWh
$11
-
kW-mo/yr
- -
05 2.4231: Reduce the pressure of compressed air to the minimum required $168 - $64
1,034
kWh
$104
-
kW-mo/yr
- -
06 2.6218: Turn off equipment when not in use $253 - $97
1,560
kWh
$156
-
kW-mo/yr
- -
07 2.7111: Reduce illumination to minimum necessary levels $1,846 - $812
13,102
kWh
$1,034
-
kW-mo/yr
- -
08 2.7261: Install timers and/or thermostats $463 $915 - - - $463
-
MMBtu
09 2.7444: Close holes and openings in building such as broken windows $9,018 $112 $1,378
22,226
kWh
$2,227
-
kW-mo/yr
- $5,413
-
MMBtu
10 4.821: Pay bills on time to avoid late fees $214 - - - $214 -
TOTAL RECOMMENDED $29,688 $19,479 $6,391
103,113
kWh
$4,867
-
kW-mo/yr
$214 $18,216
-
MMBtu
TOTAL IMPLEMENTED - - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings