ITAC Assessment: MUCM28
ITAC logo
ITAC Assessment: MUCM28
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2025
Principal Product HVAC Equipment
NAICS 238220: Plumbing, Heating, and Air-Conditioning Contractors
SIC 1711: Plumbing, Heating and Air-Conditioning
Sales Range $10
M
to 50
M
# of Employees 175
Plant Area 30,000
ft2
Annual Production 3,700
units
Production Hrs. Annual 3,120
hrs
Location (State) Michigan

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $31,238 220,588
kWh
Electricity Fees $7,225 -
Natural Gas $15,224 1,491
MMBtu
TOTAL YEARLY COSTS $53,687
RECOMMENDED SAVINGS* $11,996 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings
01 2.7447: Install vinyl strip / high speed / air curtain doors $6,696 $11,326 $(-150.0)
(-1,053)
kWh
$6,846
-
MMBtu
02 2.7221: Lower temperature during the winter season and vice-versa $2,532 - $1,536
10,818
kWh
$996
-
MMBtu
03 2.4231: Reduce the pressure of compressed air to the minimum required $206 - $206
1,466
kWh
-
04 2.7111: Reduce illumination to minimum necessary levels $1,188 - $1,188
6,552
kWh
-
05 2.7121: Utilize daylight whenever possible in lieu of artificial light $720 - $720
5,070
kWh
-
06 2.7135: Install occupancy sensors $100 $438 $100
702
kWh
-
07 2.7142: Utilize higher efficiency lamps and/or ballasts $123 $468 $123
867
kWh
-
08 2.7261: Install timers and/or thermostats $306 $217 - $306
-
MMBtu
09 2.7492: Use proper thickness of insulation on building envelope $125 $143 $48
341
kWh
$76
-
MMBtu
TOTAL RECOMMENDED $11,996 $12,592 $3,772
24,762
kWh
$8,224
-
MMBtu
TOTAL IMPLEMENTED - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs