Assessment Year 2026
Principal Product Molding and Injection Parts and Machines
NAICS 333249: Other Industrial Machinery Manufacturing
SIC 3559: Special Industry Machinery, Not Elsewhere Classified
Sales Range $50
M
to 100
M
# of Employees 180
Plant Area 333,000
ft2
Annual Production 6,181
units
Production Hrs. Annual 4,959
hrs
Location (State) Michigan

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $251,796 2,842,231
kWh
Electricity Demand $33,606 9,745
kW-mo/yr
Electricity Fees $54,530 -
Natural Gas $94,369 14,247
MMBtu
Other Gas $10,345 1
MMBtu
TOTAL YEARLY COSTS $444,646
RECOMMENDED SAVINGS* $65,337 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings
01 2.7261: Install timers and/or thermostats $47,502 $85 $342
3,838
kWh
$176
-
kW-mo/yr
- $46,984
-
MMBtu
02 2.7135: Install occupancy sensors $5,702 $1,176 $5,212
58,556
kWh
$491
-
kW-mo/yr
- -
03 2.3132: Recharge batteries on during off-peak demand periods $253 $345 - - $253 -
04 2.3212: Optimize plant power factor $5,236 $38,117 - - $5,236 -
05 2.4322: Use or replace with energy efficient substitutes $75 $650 $74
837
kWh
$0.0
-
kW-mo/yr
- -
06 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $896 - $819
9,202
kWh
$77
-
kW-mo/yr
- -
07 2.6218: Turn off equipment when not in use $3,495 - $3,319
37,293
kWh
$176
-
kW-mo/yr
- -
08 2.7124: Make a practice of turning off lights when not needed $35 $84 $32
364
kWh
$3
-
kW-mo/yr
- -
09 2.7134: Use photocell controls $237 $360 $198
2,223
kWh
$39
-
kW-mo/yr
- -
10 2.7142: Utilize higher efficiency lamps and/or ballasts $49 $176 $47
526
kWh
$2
-
kW-mo/yr
- -
11 2.7142: Utilize higher efficiency lamps and/or ballasts $1,384 $248 $1,155
12,973
kWh
$229
-
kW-mo/yr
- -
12 2.7221: Lower temperature during the winter season and vice-versa $160 - - - - $160
-
MMBtu
13 2.7444: Close holes and openings in building such as broken windows $311 $91 - - - $311
-
MMBtu
TOTAL RECOMMENDED $65,337 $41,332 $11,197
125,812
kWh
$1,195
-
kW-mo/yr
$5,489 $47,456
-
MMBtu
TOTAL IMPLEMENTED - - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs