| Assessment Year | 2024 |
|---|---|
| Principal Product | returnable packaging |
| NAICS | 326199: All Other Plastics Product Manufacturing |
| SIC | 3089: Plastics Products, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 90 |
| Plant Area |
76,000
ft2
|
| Annual Production | 2,265,699
units
|
| Production Hrs. Annual | 6,528
hrs
|
| Location (State) | Michigan |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $214,582 | 2,627,357 |
kWh
|
$0.082 |
| Electricity Demand | $70,983 | 3,213 |
kW-mo/yr
|
$22.09 |
| Electricity Fees | $37,274 | - |
|
- |
| Natural Gas | $44,121 | 4,804 |
MMBtu
|
$9.19 |
| Other Gas | $1,235 | 1 |
MMBtu
|
$1,235.00 |
| TOTAL YEARLY COSTS | $368,194 | |||
| RECOMMENDED SAVINGS* | $26,411 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $20,256 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $7,214 | $34 |
$4,785
59,812
kWh
|
$2,429
-
kW-mo/yr
|
- | |
| 02 | 2.6218: Turn off equipment when not in use | $19 | $66 |
$14
178
kWh
|
$5
-
kW-mo/yr
|
- | |
| 03 | 2.6218: Turn off equipment when not in use | $11,726 | - |
$7,779
97,239
kWh
|
$3,947
-
kW-mo/yr
|
- | |
| 04 | 2.7135: Install occupancy sensors | $184 | $84 |
$176
2,203
kWh
|
$8
-
kW-mo/yr
|
- | |
| 05 | 2.7261: Install timers and/or thermostats | $285 | $367 |
$126
1,576
kWh
|
$159
-
kW-mo/yr
|
- | |
| 06 | 2.7444: Close holes and openings in building such as broken windows | $1,133 | $555 | - | - |
$1,133
-
MMBtu
|
|
| 07 | 2.9114: Use solar heat to make electricty | $5,850 | $45,513 |
$3,841
48,012
kWh
|
$2,009
-
kW-mo/yr
|
- | |
| TOTAL RECOMMENDED | $26,411 | $46,619 |
$16,721
209,020
kWh
|
$8,557
-
kW-mo/yr
|
$1,133
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $20,256 | $673 |
$12,740
159,254
kWh
|
$6,383
-
kW-mo/yr
|
$1,133
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs