ITAC Assessment: MU0046
ITAC logo
ITAC Assessment: MU0046
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2024
Principal Product light products and simple furniture products
NAICS 335122: Commercial, Industrial, and Institutional Electric Lighting Fixture Manufacturing
SIC 3648: Lighting Equipment, Not Elsewhere Classified
Sales Range $10
M
to 50
M
# of Employees 79
Plant Area 100,000
ft2
Annual Production 200,000
units
Production Hrs. Annual 4,420
hrs
Location (State) Michigan

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $71,756 851,106
kWh
Electricity Demand $14,450 3,083
kW-mo/yr
Electricity Fees $21,980 -
Natural Gas $52,352 6,075
MMBtu
Waste Disposal Costs
Water Usage $11,968 1,674
Tgal
TOTAL YEARLY COSTS $172,506
RECOMMENDED SAVINGS* $87,147 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $3,562

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Administrative Changes Savings
01 2.2449: Recover heat from exhausted steam, hot air or hot water $465 $484 - - $465
-
MMBtu
-
02 2.2449: Recover heat from exhausted steam, hot air or hot water $7,422 $9,923 - - $7,422
-
MMBtu
-
03 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $1,153 - $995
12,438
kWh
$158
-
kW-mo/yr
- -
04 2.4221: Install compressor air intakes in coolest locations $340 $2,498 $293
3,660
kWh
$47
-
kW-mo/yr
- -
05 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $160 $17 $153
1,914
kWh
$7
-
kW-mo/yr
- -
06 2.4231: Reduce the pressure of compressed air to the minimum required $814 - $702
8,775
kWh
$112
-
kW-mo/yr
- -
07 2.4322: Use or replace with energy efficient substitutes $320 $1,932 $87
1,082
kWh
$234
-
kW-mo/yr
- -
08 2.6218: Turn off equipment when not in use $426 - $395
4,935
kWh
$32
-
kW-mo/yr
- -
09 2.7134: Use photocell controls $74 $706 $64
796
kWh
$10
-
kW-mo/yr
- -
10 2.7444: Close holes and openings in building such as broken windows $844 $555 - - $844
-
MMBtu
-
11 2.7491: Insulate glazing, walls, ceilings, and roofs $1,303 $13,605 - - $1,303
-
MMBtu
-
12 2.8121: Apply for tax-free status for energy purchases $3,810 - - - - $3,810
13 2.9114: Use solar heat to make electricty $70,016 $432,400 $70,016
833,528
kWh
- - -
TOTAL RECOMMENDED $87,147 $462,120 $72,704
867,127
kWh
$600
-
kW-mo/yr
$10,033
-
MMBtu
$3,810
TOTAL IMPLEMENTED $3,562 $16,744 $1,400
17,501
kWh
$394
-
kW-mo/yr
$1,768
-
MMBtu
-
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Administrative Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs