Assessment Year 2021
Principal Product Health care/retail labels
NAICS 322220: Paper Bag and Coated and Treated Paper Manufacturing
SIC 2672: Coated and Laminated Paper, Not Elsewhere Classified
Sales Range $10
M
to 50
M
# of Employees 77
Plant Area 73,350
ft2
Annual Production 15,000,000
units
Production Hrs. Annual 6,240
hrs
Location (State) New York

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $178,166 3,979,868
kWh
Electricity Demand $131,358 10,651
kW-mo/yr
Electricity Fees $1,779 -
Natural Gas $16,849 2,739
MMBtu
TOTAL YEARLY COSTS $328,152
RECOMMENDED SAVINGS* $7,525 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $2,117

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Administrative Changes Savings One-time Revenue or Avoided Cost Savings
01 2.4239: Eliminate or reduce compressed air usage $1,396 - $1,396
31,029
kWh
- - - -
02 2.7224: Reduce space conditioning during non-working hours $30 - - - $30
-
MMBtu
- -
03 2.4322: Use or replace with energy efficient substitutes $2,156 $40 $861
19,125
kWh
$1,295
-
kW-mo/yr
- - -
04 2.2443: Re-use or recycle hot or cold process exhaust air $945 $340 - - $945
-
MMBtu
- -
05 2.7142: Utilize higher efficiency lamps and/or ballasts $579 $155 $339
7,534
kWh
$127
-
kW-mo/yr
- $38 $75
06 2.7135: Install occupancy sensors $142 $176 $142
3,154
kWh
- - - -
07 2.7314: Reduce ventilation air $1,358 $1,749 $518
11,522
kWh
- $840
-
MMBtu
- -
08 2.6211: Conserve energy by efficient use of vending machines $79 $186 $79
1,752
kWh
- - - -
09 3.1161: Eliminate/reduce an operation $840 $2,772 - - - - $840
TOTAL RECOMMENDED $7,525 $5,418 $3,335
74,116
kWh
$1,422
-
kW-mo/yr
$1,814
-
MMBtu
$38 $915
TOTAL IMPLEMENTED $2,117 $331 $1,877
41,717
kWh
$127
-
kW-mo/yr
- $38 $75
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Administrative Changes Savings One-time Revenue or Avoided Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs