ITAC Assessment: MU0043
ITAC logo
ITAC Assessment: MU0043
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2023
Principal Product Motor vehicle metal stamping products
NAICS 336370: Motor Vehicle Metal Stamping
SIC 3499: Fabricated Metal Products, Not Elsewhere Classified
Sales Range $10
M
to 50
M
# of Employees 90
Plant Area 335,000
ft2
Annual Production 5,990,400
pieces
Production Hrs. Annual 7,488
hrs
Location (State) Michigan

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $212,854 3,874,107
kWh
Electricity Demand $143,410 8,982
kW-mo/yr
Electricity Fees $34,386 -
Natural Gas $95,490 11,184
MMBtu
TOTAL YEARLY COSTS $486,140
RECOMMENDED SAVINGS* $84,265 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $21,118

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
01 2.4133: Use most efficient type of electric motors $116 $319 $116
2,315
kWh
- -
02 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $2,700 $7,887 $998
19,950
kWh
$1,702
-
kW-mo/yr
-
03 2.4221: Install compressor air intakes in coolest locations $1,957 $2,281 $1,289
25,778
kWh
$668
-
kW-mo/yr
-
04 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $228 $480 $151
3,013
kWh
$77
-
kW-mo/yr
-
05 2.6125: Keep equipment clean $33 - $22
440
kWh
$11
-
kW-mo/yr
-
06 2.7243: Improve air circulation with destratification fans / other methods $20,803 $28,063 - - $20,803
-
MMBtu
07 2.7444: Close holes and openings in building such as broken windows $54 $51 - - $54
-
MMBtu
08 2.7447: Install vinyl strip / high speed / air curtain doors $39,395 $128,601 - - $39,395
-
MMBtu
09 2.9114: Use solar heat to make electricty $18,979 $158,490 $9,157
183,139
kWh
$9,822
-
kW-mo/yr
-
TOTAL RECOMMENDED $84,265 $326,172 $11,732
234,635
kWh
$12,280
-
kW-mo/yr
$60,252
-
MMBtu
TOTAL IMPLEMENTED $21,118 $28,594 $173
3,453
kWh
$88
-
kW-mo/yr
$20,857
-
MMBtu
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs