Assessment Year | 2023 |
---|---|
Principal Product | Automotive Equipment for Off Road Vehicle Applications |
NAICS | 334419: Other Electronic Component Manufacturing |
SIC | 3679: Electronic Components, Not Elsewhere Classified |
Sales Range | $50 M to 100M |
# of Employees | 220 |
Plant Area |
175,000
ft2
|
Annual Production | 2,000,000
pieces
|
Production Hrs. Annual | 6,300
hrs
|
Location (State) | Michigan |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $269,132 | 3,563,486 |
kWh
|
$0.076 |
Electricity Demand | $176,440 | 9,232 |
kW-mo/yr
|
$19.11 |
Electricity Fees | $20,779 | - |
|
- |
Natural Gas | $27,093 | 2,301 |
MMBtu
|
$11.78 |
TOTAL YEARLY COSTS | $493,445 | |||
RECOMMENDED SAVINGS* | $44,789 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $15,281 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.4221: Install compressor air intakes in coolest locations | $1,852 | - |
$1,378
18,129
kWh
|
$475
-
kW-mo/yr
|
- | - | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $388 | - |
$289
3,797
kWh
|
$99
-
kW-mo/yr
|
- | - | |
03 | 2.4322: Use or replace with energy efficient substitutes | $10,129 | $49,885 |
$840
11,052
kWh
|
$289
-
kW-mo/yr
|
- | $9,000 | |
04 | 2.7111: Reduce illumination to minimum necessary levels | $1,737 | - |
$1,291
16,993
kWh
|
$445
-
kW-mo/yr
|
- | - | |
05 | 2.7134: Use photocell controls | $756 | - |
$756
9,951
kWh
|
- | - | - | |
06 | 2.7135: Install occupancy sensors | $1,296 | $30 |
$1,296
17,051
kWh
|
- | - | - | |
07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,370 | - |
$1,370
18,023
kWh
|
- | - | - | |
08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $305 | $1,240 |
$227
2,987
kWh
|
$78
-
kW-mo/yr
|
- | - | |
09 | 2.7212: Install or upgrade insulation on hvac distribution systems | $3,433 | $3,037 |
$961
12,650
kWh
|
$806
-
kW-mo/yr
|
$1,665
-
MMBtu
|
- | |
10 | 2.7221: Lower temperature during the winter season and vice-versa | $902 | - |
$356
4,680
kWh
|
$122
-
kW-mo/yr
|
$424
-
MMBtu
|
- | |
11 | 2.7231: Use radiant heater for spot heating | $4,730 | $5,760 | - | - |
$4,730
-
MMBtu
|
- | |
12 | 2.7447: Install vinyl strip / high speed / air curtain doors | $12,544 | $17,271 |
$1,550
20,398
kWh
|
- |
$10,994
-
MMBtu
|
- | |
13 | 2.9114: Use solar heat to make electricty | $5,347 | $25,171 |
$5,347
53,468
kWh
|
- | - | - | |
TOTAL RECOMMENDED | $44,789 | $102,394 |
$15,661
189,179
kWh
|
$2,315
-
kW-mo/yr
|
$17,813
-
MMBtu
|
$9,000 | ||
TOTAL IMPLEMENTED | $15,281 | $49,885 |
$4,902
64,495
kWh
|
$955
-
kW-mo/yr
|
$424
-
MMBtu
|
$9,000 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs