Assessment Year | 2002 |
---|---|
Principal Product | Fabricated steel structures |
NAICS |
n/a
|
SIC | 3441: Fabricated Structural Metal |
Sales Range | $10 M to 50M |
# of Employees | 167 |
Plant Area |
70,000
ft2
|
Annual Production | 12,000
ton
|
Production Hrs. Annual | 5,993
hrs
|
Location (State) | Mississippi |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $128,255 | 2,618,992 |
kWh
|
$0.049 |
Electricity Demand | $20,956 | 7,635 |
kW-mo/yr
|
$2.74 |
Electricity Fees | $24,085 | - |
|
- |
Natural Gas | $76,122 | 7,778 |
MMBtu
|
$9.79 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $518,210 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $9,385 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Other Liquid (haz) Savings | Primary Product Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.2437: Recover waste heat from equipment | $7,110 | $3,070 | - | - | - |
$7,110
-
MMBtu
|
- | - | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $8,645 | $437 |
$6,319
132,474
kWh
|
- | $2,326 | - | - | - | |
03 | 2.7261: Install timers and/or thermostats | $740 | $827 |
$541
11,430
kWh
|
- | $199 | - | - | - | |
04 | 2.4221: Install compressor air intakes in coolest locations | $534 | $242 |
$357
7,620
kWh
|
$44
-
kW-mo/yr
|
$133 | - | - | - | |
05 | 3.6124: Burn waste oil for heat | $1,181 | $409 | - | - | - |
$851
-
MMBtu
|
$330
-
gal
|
- | |
06 | 4.511: Expand operations into unused space | $500,000 | $1,000,000 | - | - | - | - | - | $500,000 | |
TOTAL RECOMMENDED | $518,210 | $1,004,985 |
$7,217
151,524
kWh
|
$44
-
kW-mo/yr
|
$2,658 |
$7,961
-
MMBtu
|
$330
-
gal
|
$500,000 | ||
TOTAL IMPLEMENTED | $9,385 | $1,264 |
$6,860
143,904
kWh
|
- | $2,525 | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Other Liquid (haz) Savings | Primary Product Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs