Assessment Year | 2020 |
---|---|
Principal Product | Fire Protection, Water, and Wastewater Pumps |
NAICS | 333911: Pump and Pumping Equipment Manufacturing |
SIC | 3561: Pumps and Pumping Equipment |
Sales Range | $100 M to 500M |
# of Employees | 291 |
Plant Area |
190,000
ft2
|
Annual Production | 5,211
units
|
Production Hrs. Annual | 5,148
hrs
|
Location (State) | Georgia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $431,824 | 4,890,095 |
kWh
|
$0.088 |
Natural Gas | $145,461 | 12,808 |
MMBtu
|
$11.36 |
TOTAL YEARLY COSTS | $577,285 | |||
RECOMMENDED SAVINGS* | $127,527 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $32,838 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.4231: Reduce the pressure of compressed air to the minimum required | $3,860 | $300 |
$3,860
43,861
kWh
|
|
02 | 2.2625: Chill water to the highest temperature possible | $956 | $250 |
$956
10,862
kWh
|
|
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $4,480 | $3,500 |
$4,480
50,914
kWh
|
|
04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,602 | $1,267 |
$1,602
18,201
kWh
|
|
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $32,838 | $36,630 |
$32,838
373,158
kWh
|
|
06 | 2.9114: Use solar heat to make electricty | $83,791 | $569,779 |
$83,791
949,068
kWh
|
|
TOTAL RECOMMENDED | $127,527 | $611,725 |
$127,527
1,446,064
kWh
|
||
TOTAL IMPLEMENTED | $32,838 | $36,630 |
$32,838
373,158
kWh
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs