Assessment Year | 2001 |
---|---|
Principal Product | Injection Molded Parts |
NAICS |
n/a
|
SIC | 3639: Household Appliances, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 865 |
Plant Area |
900,000
ft2
|
Annual Production | 0
units
|
Production Hrs. Annual | 8,400
hrs
|
Location (State) | Mississippi |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $353,842 | 36,686,645 |
kWh
|
$0.010 |
Electricity Demand | $484,810 | 96,962 |
kW-mo/yr
|
$5.00 |
Electricity Fees | $969,450 | - |
|
- |
Natural Gas | $18,023 | 4,868 |
MMBtu
|
$3.70 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $877,999 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $128,442 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Fees Savings | Primary Product Savings |
---|---|---|---|---|---|---|---|
01 | 2.7229: Air condition only space necessary | $133,472 | $38,250 |
$21,133
4,449,710
kWh
|
$112,339 | - | |
02 | 2.7228: Avoid introducing hot, humid, or dirty air into hvac system | $23,451 | $3,230 |
$3,713
781,702
kWh
|
$19,738 | - | |
03 | 2.2511: Insulate bare equipment | $8,374 | $3,053 |
$1,326
279,142
kWh
|
$7,048 | - | |
04 | 2.6231: Utilize controls to operate equipment only when needed | $5,493 | $1,893 |
$870
183,096
kWh
|
$4,623 | - | |
05 | 2.4221: Install compressor air intakes in coolest locations | $964 | $1,459 |
$153
32,118
kWh
|
$811 | - | |
06 | 4.511: Expand operations into unused space | $583,296 | $1,050,000 | - | $583,296 | - | |
07 | 4.445: Install equipment to move product | $122,949 | $105,000 | - | - | $122,949 | |
TOTAL RECOMMENDED | $877,999 | $1,202,885 |
$27,195
5,725,768
kWh
|
$727,855 | $122,949 | ||
TOTAL IMPLEMENTED | $128,442 | $106,893 |
$870
183,096
kWh
|
$4,623 | $122,949 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Fees Savings | Primary Product Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs