Assessment Year | 2000 |
---|---|
Principal Product | Parts cleaning and stripping |
NAICS |
n/a
|
SIC | 2841: Soap and Other Detergents, Except Specialty Cleaners |
Sales Range | $1 M to 5M |
# of Employees | 40 |
Plant Area |
58,000
ft2
|
Annual Production | 5,907,069
pieces
|
Production Hrs. Annual | 2,000
hrs
|
Location (State) | Mississippi |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $25,634 | 522,274 |
kWh
|
$0.049 |
Electricity Demand | $5,720 | 1,692 |
kW-mo/yr
|
$3.38 |
Electricity Fees | $2,498 | - |
|
- |
Natural Gas | $58,164 | 9,422 |
MMBtu
|
$6.17 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $26,872 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $20,405 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Water Disposal Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.2414: Use waste heat from hot flue gases to preheat | $2,872 | $1,710 | - | - | - |
$2,872
-
MMBtu
|
- | - | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,747 | $191 |
$2,561
77,374
kWh
|
- | $186 | - | - | - | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $635 | $2,618 |
$238
7,034
kWh
|
$354
-
kW-mo/yr
|
$43 | - | - | - | |
04 | 2.7134: Use photocell controls | $240 | $222 |
$224
6,741
kWh
|
- | $16 | - | - | - | |
05 | 2.7261: Install timers and/or thermostats | $238 | $236 |
$222
3,517
kWh
|
- | $16 | - | - | - | |
06 | 2.4221: Install compressor air intakes in coolest locations | $206 | $65 |
$103
3,224
kWh
|
$89
-
kW-mo/yr
|
$14 | - | - | - | |
07 | 2.2511: Insulate bare equipment | $169 | $381 | - | - | - |
$169
-
MMBtu
|
- | - | |
08 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $831 | $599 |
$506
15,240
kWh
|
$629
-
kW-mo/yr
|
$82 |
$(-386.0)
-
MMBtu
|
- | - | |
09 | 2.8121: Apply for tax-free status for energy purchases | $5,488 | $50 | - | - | $1,372 | - | - | $4,116 | |
10 | 2.8121: Apply for tax-free status for energy purchases | $11,932 | $50 | - | - | - |
$2,983
-
MMBtu
|
- | $8,949 | |
11 | 4.821: Pay bills on time to avoid late fees | $1,514 | $50 | - | - | - | - |
$1,514
-
Tgal
|
- | |
TOTAL RECOMMENDED | $26,872 | $6,172 |
$3,854
113,130
kWh
|
$1,072
-
kW-mo/yr
|
$1,729 |
$5,638
-
MMBtu
|
$1,514
-
Tgal
|
$13,065 | ||
TOTAL IMPLEMENTED | $20,405 | $527 |
$2,783
80,891
kWh
|
- | $1,574 |
$2,983
-
MMBtu
|
- | $13,065 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Water Disposal Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs