Assessment Year | 2000 |
---|---|
Principal Product | Sinuous Springs |
NAICS |
n/a
|
SIC | 3495: Wire Springs |
Sales Range | $10 M to 50M |
# of Employees | 215 |
Plant Area |
140,000
ft2
|
Annual Production | 125,000,000
pieces
|
Production Hrs. Annual | 4,200
hrs
|
Location (State) | Mississippi |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $55,962 | 1,072,180 |
kWh
|
$0.052 |
Electricity Demand | $17,069 | 3,669 |
kW-mo/yr
|
$4.65 |
Electricity Fees | $2,535 | - |
|
- |
LPG | $83,460 | 10,445 |
MMBtu
|
$7.99 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $15,330 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $11,286 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | LPG Savings | Personnel Changes Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.2442: Preheat combustion air with waste heat | $3,027 | $1,383 | - | - | - |
$3,027
-
MMBtu
|
- | - | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,307 | $309 |
$1,288
36,300
kWh
|
- | $19 | - | - | - | |
03 | 2.7261: Install timers and/or thermostats | $624 | $708 |
$615
17,340
kWh
|
- | $9 | - | - | - | |
04 | 2.6214: Shut off pilots in standby equipment | $346 | $40 | - | - | - |
$346
-
MMBtu
|
- | - | |
05 | 2.7124: Make a practice of turning off lights when not needed | $951 | $100 |
$324
9,120
kWh
|
$613
-
kW-mo/yr
|
$14 | - | - | - | |
06 | 2.4221: Install compressor air intakes in coolest locations | $66 | $151 |
$25
705
kWh
|
$40
-
kW-mo/yr
|
$1 | - | - | - | |
07 | 4.652: Replace existing equipment with more suitable substitutes | $9,009 | $7,649 |
$199
5,621
kWh
|
$(-160.0)
-
kW-mo/yr
|
- | - | $2,970 | $6,000 | |
TOTAL RECOMMENDED | $15,330 | $10,340 |
$2,451
69,086
kWh
|
$493
-
kW-mo/yr
|
$43 |
$3,373
-
MMBtu
|
$2,970 | $6,000 | ||
TOTAL IMPLEMENTED | $11,286 | $8,706 |
$2,102
59,261
kWh
|
$(-160.0)
-
kW-mo/yr
|
$28 |
$346
-
MMBtu
|
$2,970 | $6,000 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | LPG Savings | Personnel Changes Savings | One-time Revenue or Avoided Cost Savings |