ITAC Assessment: MS0152
ITAC logo
ITAC Assessment: MS0152
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2000
Principal Product Heat Exchangers
NAICS
n/a
SIC 3585: Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment
Sales Range $10
M
to 50
M
# of Employees 350
Plant Area 217,000
ft2
Annual Production 57,200
pieces
Production Hrs. Annual 7,440
hrs
Location (State) Mississippi

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $258,243 5,770,223
kWh
Electricity Demand $41,569 11,833
kW-mo/yr
Electricity Fees $(-20,484.0) -
Natural Gas $60,423 17,310
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $27,198 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $12,429

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings Water Disposal Savings Other Liquid (non-haz) Savings Water Consumption Savings
01 2.4221: Install compressor air intakes in coolest locations $331 $136 $362
10,551
kWh
$52
-
kW-mo/yr
$(-83.0) - - - -
02 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $8,518 $457 $11,816
343,787
kWh
- $(-3,298.0) - - - -
03 2.2437: Recover waste heat from equipment $3,651 $3,747 - - - $3,651
-
MMBtu
- - -
04 2.7261: Install timers and/or thermostats $3,911 $2,652 $5,426
157,972
kWh
- $(-1,515.0) - - - -
05 2.2414: Use waste heat from hot flue gases to preheat $1,407 $4,000 - - - $1,407
-
MMBtu
- - -
06 3.6124: Burn waste oil for heat $432 $1,974 - - - $232
-
MMBtu
- $200
-
gal
-
07 3.4111: Use closed cycle process to minimize waste water production $8,948 $4,500 - - - - $3,029
-
Tgal
- $5,919
-
Tgal
TOTAL RECOMMENDED $27,198 $17,466 $17,604
512,310
kWh
$52
-
kW-mo/yr
$(-4,896.0) $5,290
-
MMBtu
$3,029
-
Tgal
$200
-
gal
$5,919
-
Tgal
TOTAL IMPLEMENTED $12,429 $3,109 $17,242
501,759
kWh
- $(-4,813.0) - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings Water Disposal Savings Other Liquid (non-haz) Savings Water Consumption Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs