Assessment Year | 1999 |
---|---|
Principal Product | Manufactured Homes |
NAICS |
n/a
|
SIC | 2451: Mobile Homes |
Sales Range | $10 M to 50M |
# of Employees | 234 |
Plant Area |
115,185
ft2
|
Annual Production | 2,080
pieces
|
Production Hrs. Annual | 2,600
hrs
|
Location (State) | Mississippi |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $74,165 | 1,292,497 |
kWh
|
$0.057 |
Electricity Demand | $14,632 | 6,178 |
kW-mo/yr
|
$2.37 |
Electricity Fees | $10,709 | - |
|
- |
Natural Gas | $9,205 | 1,787 |
MMBtu
|
$5.15 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $289,158 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Personnel Changes Savings | Increase in Production Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.4221: Install compressor air intakes in coolest locations | $1,570 | $133 |
$1,268
26,671
kWh
|
$323
-
kW-mo/yr
|
$(-21.0) | - | - | - | |
02 | 2.6231: Utilize controls to operate equipment only when needed | $561 | $334 |
$622
12,896
kWh
|
- | $(-61.0) | - | - | - | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $5,618 | $1,130 |
$6,255
136,577
kWh
|
- | $(-637.0) | - | - | - | |
04 | 2.2437: Recover waste heat from equipment | $1,296 | $3,418 | - | - | - |
$1,296
-
MMBtu
|
- | - | |
05 | 2.6232: Install set-back timers | $717 | $472 |
$709
12,309
kWh
|
- | $8 | - | - | - | |
06 | 4.514: Re-arrange equipment layout to reduce handling costs | $279,396 | $26,310 | - | - | - | - | $10,296 | $269,100 | |
TOTAL RECOMMENDED | $289,158 | $31,797 |
$8,854
188,453
kWh
|
$323
-
kW-mo/yr
|
$(-711.0) |
$1,296
-
MMBtu
|
$10,296 | $269,100 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Personnel Changes Savings | Increase in Production Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs