Assessment Year | 1999 |
---|---|
Principal Product | Vinyl Binders |
NAICS |
n/a
|
SIC | 2782: Blankbooks, Looseleaf Binders and Devices |
Sales Range | $100 M to 500M |
# of Employees | 550 |
Plant Area |
365,000
ft2
|
Annual Production | 80,000,000
pieces
|
Production Hrs. Annual | 7,584
hrs
|
Location (State) | Mississippi |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $420,932 | 11,593,494 |
kWh
|
$0.036 |
Electricity Demand | $124,587 | 27,686 |
kW-mo/yr
|
$4.50 |
Electricity Fees | $(-28,440.0) | - |
|
- |
Natural Gas | $16,371 | 3,154 |
MMBtu
|
$5.19 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $303,647 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $168,589 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Solid Waste (haz) Savings | Personnel Changes Savings | Administrative Changes Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $11,685 | $1,202 |
$14,187
450,469
kWh
|
- | $(-2,502.0) | - | - | - | - | - | |
02 | 2.7261: Install timers and/or thermostats | $584 | $236 |
$709
22,567
kWh
|
- | $(-125.0) | - | - | - | - | - | |
03 | 2.6214: Shut off pilots in standby equipment | $140 | $54 | - | - | - |
$140
-
MMBtu
|
- | - | - | - | |
04 | 2.3191: Use demand controller or load shedder | $3,782 | $11,500 | - |
$3,726
-
kW-mo/yr
|
$56 | - | - | - | - | - | |
05 | 2.4221: Install compressor air intakes in coolest locations | $393 | $101 |
$360
11,430
kWh
|
$95
-
kW-mo/yr
|
$(-62.0) | - | - | - | - | - | |
06 | 3.7196: Use re-usable filters | $14,954 | $14,960 | - | - | - | - |
$47
-
lb
|
- | - | $14,907 | |
07 | 4.512: Condense operation into one building | $115,929 | $8,265 |
$11,198
355,510
kWh
|
$4,257
-
kW-mo/yr
|
$(-1,910.0) | - | - | $102,384 | - | - | |
08 | 4.515: Install shelves / racks to utilize unused space | $156,180 | $23,010 | - | - | - | - | - | - | $156,180 | - | |
TOTAL RECOMMENDED | $303,647 | $59,328 |
$26,454
839,976
kWh
|
$8,078
-
kW-mo/yr
|
$(-4,543.0) |
$140
-
MMBtu
|
$47
-
lb
|
$102,384 | $156,180 | $14,907 | ||
TOTAL IMPLEMENTED | $168,589 | $24,502 |
$14,896
473,036
kWh
|
- | $(-2,627.0) |
$140
-
MMBtu
|
- | - | $156,180 | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Solid Waste (haz) Savings | Personnel Changes Savings | Administrative Changes Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs