Assessment Year | 1995 |
---|---|
Principal Product | High Nutrition Pet Food |
NAICS |
n/a
|
SIC | 2047: Dog and Cat Food |
Sales Range | $100 M to 500M |
# of Employees | 275 |
Plant Area |
142,000
ft2
|
Annual Production | 313,000,000
lb
|
Production Hrs. Annual | 2,200
hrs
|
Location (State) | Kentucky |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $869,809 | 18,568,875 |
kWh
|
$0.047 |
Natural Gas | $348,346 | 146,223 |
MMBtu
|
$2.38 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $67,321 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $9,890 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,773 | $2,117 |
$1,773
37,808
kWh
|
- | |
02 | 2.4133: Use most efficient type of electric motors | $152 | $450 |
$152
3,224
kWh
|
- | |
03 | 2.3212: Optimize plant power factor | $54,149 | $37,248 |
$54,149
-
kWh
|
- | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $370 | $40 |
$370
7,913
kWh
|
- | |
05 | 2.2121: Increase amount of condensate returned | $9,738 | $625 | - |
$9,738
-
MMBtu
|
|
06 | 2.1233: Analyze flue gas for proper air/fuel ratio | $1,139 | $1,000 | - |
$1,139
-
MMBtu
|
|
TOTAL RECOMMENDED | $67,321 | $41,480 |
$56,444
48,945
kWh
|
$10,877
-
MMBtu
|
||
TOTAL IMPLEMENTED | $9,890 | $1,075 |
$152
3,224
kWh
|
$9,738
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs