| Assessment Year | 1995 |
|---|---|
| Principal Product | Wood Picture Frames |
| NAICS |
n/a
|
| SIC | 2499: Wood Products, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 127 |
| Plant Area |
185,000
ft2
|
| Annual Production | 3,218,003
pieces
|
| Production Hrs. Annual | 4,000
hrs
|
| Location (State) | Mississippi |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $152,439 | 2,534,584 |
kWh
|
$0.060 |
| Natural Gas | $3,386 | 745 |
MMBtu
|
$4.54 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $19,655 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $14,565 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,927 | $5,513 |
$3,927
47,773
kWh
|
- | |
| 02 | 2.4221: Install compressor air intakes in coolest locations | $1,106 | $450 |
$1,106
16,413
kWh
|
- | |
| 03 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $2,972 | - |
$2,972
-
kWh
|
- | |
| 04 | 2.7261: Install timers and/or thermostats | $7,666 | $440 |
$7,666
162,368
kWh
|
- | |
| 05 | 2.2437: Recover waste heat from equipment | $3,984 | $3,000 | - |
$3,984
-
MMBtu
|
|
| TOTAL RECOMMENDED | $19,655 | $9,403 |
$15,671
226,554
kWh
|
$3,984
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $14,565 | $5,953 |
$14,565
210,141
kWh
|
- | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs