Assessment Year | 1995 |
---|---|
Principal Product | Wood Picture Frames |
NAICS |
n/a
|
SIC | 2499: Wood Products, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 127 |
Plant Area |
185,000
ft2
|
Annual Production | 3,218,003
pieces
|
Production Hrs. Annual | 4,000
hrs
|
Location (State) | Mississippi |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $152,439 | 2,534,584 |
kWh
|
$0.060 |
Natural Gas | $3,386 | 745 |
MMBtu
|
$4.54 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $19,655 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $14,565 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,927 | $5,513 |
$3,927
47,773
kWh
|
- | |
02 | 2.4221: Install compressor air intakes in coolest locations | $1,106 | $450 |
$1,106
16,413
kWh
|
- | |
03 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $2,972 | - |
$2,972
-
kWh
|
- | |
04 | 2.7261: Install timers and/or thermostats | $7,666 | $440 |
$7,666
162,368
kWh
|
- | |
05 | 2.2437: Recover waste heat from equipment | $3,984 | $3,000 | - |
$3,984
-
MMBtu
|
|
TOTAL RECOMMENDED | $19,655 | $9,403 |
$15,671
226,554
kWh
|
$3,984
-
MMBtu
|
||
TOTAL IMPLEMENTED | $14,565 | $5,953 |
$14,565
210,141
kWh
|
- |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs