Assessment Year | 1993 |
---|---|
Principal Product | Electric Motors |
NAICS |
n/a
|
SIC | 3621: Motors and Generators |
Sales Range | $50 M to 100M |
# of Employees | 552 |
Plant Area |
380,000
ft2
|
Annual Production | 2,000,000
pieces
|
Production Hrs. Annual | 6,864
hrs
|
Location (State) | Missouri |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $541,502 | 13,646,249 |
kWh
|
$0.040 |
Natural Gas | $74,344 | 25,447 |
MMBtu
|
$2.92 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $133,033 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $21,806 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Water Disposal Savings |
---|---|---|---|---|---|---|
01 | 2.7447: Install vinyl strip / high speed / air curtain doors | $67,868 | $8,774 |
$67,868
1,710,434
kWh
|
- | |
02 | 2.2531: Re-size charging openings or add movable cover or door | $5,635 | $100 |
$5,635
142,145
kWh
|
- | |
03 | 2.2531: Re-size charging openings or add movable cover or door | $204 | - |
$204
5,275
kWh
|
- | |
04 | 3.4114: Replace city water with recycled water via cooling tower | $43,359 | $7,325 | - |
$43,359
-
Tgal
|
|
05 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $515 | $1,024 |
$515
12,896
kWh
|
- | |
06 | 2.4133: Use most efficient type of electric motors | $9,317 | $31,982 |
$9,317
234,760
kWh
|
- | |
07 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $2,548 | $1,125 |
$2,548
64,185
kWh
|
- | |
08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,346 | $777 |
$2,346
59,203
kWh
|
- | |
09 | 2.4221: Install compressor air intakes in coolest locations | $907 | $554 |
$907
22,860
kWh
|
- | |
10 | 2.4231: Reduce the pressure of compressed air to the minimum required | $334 | $20 |
$334
8,499
kWh
|
- | |
TOTAL RECOMMENDED | $133,033 | $51,681 |
$89,674
2,260,257
kWh
|
$43,359
-
Tgal
|
||
TOTAL IMPLEMENTED | $21,806 | $35,582 |
$21,806
549,823
kWh
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Water Disposal Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs