| Assessment Year | 1991 |
|---|---|
| Principal Product | FOLDING CARTONS |
| NAICS |
n/a
|
| SIC | 2675: Die-Cut Paper and Paperboard and Cardboard |
| Sales Range | $10 M to 50M |
| # of Employees | 220 |
| Plant Area |
n/a
|
| Annual Production | 400,000,000
pieces
|
| Production Hrs. Annual | 6,240
hrs
|
| Location (State) | Missouri |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $216,114 | 3,613,130 |
kWh
|
$0.060 |
| LPG | $55,819 | 7,511 |
MMBtu
|
$7.43 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $37,240 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | LPG Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|
| 01 | 3.4115: Recover and reuse cooling water | $16,673 | - |
$261
4,396
kWh
|
- | $16,412 | |
| 02 | 2.4221: Install compressor air intakes in coolest locations | $3,077 | $415 |
$3,077
51,583
kWh
|
- | - | |
| 03 | 2.4312: Improve lubrication practices | $1,978 | $96 |
$1,978
33,118
kWh
|
- | - | |
| 04 | 2.7261: Install timers and/or thermostats | $8,595 | $1,161 |
$2,626
43,962
kWh
|
$5,969
-
MMBtu
|
- | |
| 05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $3,588 | - |
$3,588
60,082
kWh
|
- | - | |
| 06 | 2.4133: Use most efficient type of electric motors | $255 | $438 |
$255
4,396
kWh
|
- | - | |
| 07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $441 | $1,184 |
$441
7,327
kWh
|
- | - | |
| 08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,633 | $584 |
$2,633
43,962
kWh
|
- | - | |
| TOTAL RECOMMENDED | $37,240 | $3,878 |
$14,859
248,826
kWh
|
$5,969
-
MMBtu
|
$16,412 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | LPG Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs