Assessment Year | 2023 |
---|---|
Principal Product | Bread Loaves |
NAICS | 311812: Commercial Bakeries |
SIC | 2041: Flour and Other Grain Mill Products |
Sales Range | $100 M to 500M |
# of Employees | 85 |
Plant Area |
175,000
ft2
|
Annual Production | 52,000,000
lb
|
Production Hrs. Annual | 8,736
hrs
|
Location (State) | Florida |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $474,446 | 9,478,000 |
kWh
|
$0.050 |
Electricity Demand | $226,262 | 15,219 |
kW-mo/yr
|
$14.87 |
Electricity Fees | $164,928 | - |
|
- |
TOTAL YEARLY COSTS | $865,636 | |||
RECOMMENDED SAVINGS* | $127,810 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $27,684 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.4224: Upgrade controls on compressors | $58,143 | $16,338 |
$41,284
825,680
kWh
|
$16,859
-
kW-mo/yr
|
- | |
02 | 2.8114: Change rate schedules or other changes in utility service | $25,845 | - | - | - | $25,845 | |
03 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $12,705 | $18,960 |
$9,018
180,358
kWh
|
$3,687
-
kW-mo/yr
|
- | |
04 | 2.4239: Eliminate or reduce compressed air usage | $10,521 | $4,259 |
$7,607
152,149
kWh
|
$2,914
-
kW-mo/yr
|
- | |
05 | 2.2622: Replace existing chiller with high efficiency model | $9,078 | $12,846 |
$6,447
128,940
kWh
|
$2,631
-
kW-mo/yr
|
- | |
06 | 2.7221: Lower temperature during the winter season and vice-versa | $6,907 | $580 |
$3,800
76,002
kWh
|
$3,107
-
kW-mo/yr
|
- | |
07 | 2.7447: Install vinyl strip / high speed / air curtain doors | $2,772 | $2,740 |
$1,969
39,370
kWh
|
$803
-
kW-mo/yr
|
- | |
08 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,839 | $2,140 |
$1,304
26,088
kWh
|
$535
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $127,810 | $57,863 |
$71,429
1,428,587
kWh
|
$30,536
-
kW-mo/yr
|
$25,845 | ||
TOTAL IMPLEMENTED | $27,684 | $2,140 |
$1,304
26,088
kWh
|
$535
-
kW-mo/yr
|
$25,845 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs