ITAC Assessment: MI0377
ITAC logo
ITAC Assessment: MI0377
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2021
Principal Product pet bottles, jars
NAICS 326160: Plastics Bottle Manufacturing
SIC 3085: Plastics Bottles
Sales Range $10
M
to 50
M
# of Employees 72
Plant Area 45,000
ft2
Annual Production 70,000,000
pieces
Production Hrs. Annual 7,344
hrs
Location (State) Florida

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $151,367 3,777,861
kWh
Electricity Demand $117,722 8,745
kW-mo/yr
Electricity Fees $37,460 -
Waste Disposal Costs
Water Usage $11,268 2,126
Tgal
Water Disposal $17,943 2,126
Tgal
TOTAL YEARLY COSTS $335,760
RECOMMENDED SAVINGS* $34,220 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Water Disposal Savings
01 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $9,975 $1,980 $3,190
79,762
kWh
$6,785
-
kW-mo/yr
-
02 2.4231: Reduce the pressure of compressed air to the minimum required $7,215 $2,100 $4,415
110,384
kWh
$2,800
-
kW-mo/yr
-
03 3.4116: Meter recycled water (to reduce sewer charges) $4,058 $1,306 - - $4,058
-
Tgal
04 2.7252: Utilize an evaporative air pre-cooler or other heat exchanger in ac system $3,560 $17,760 $2,295
57,370
kWh
$1,265
-
kW-mo/yr
-
05 2.7447: Install vinyl strip / high speed / air curtain doors $2,125 $2,048 $792
19,809
kWh
$1,333
-
kW-mo/yr
-
06 2.7229: Air condition only space necessary $1,976 $4,415 $1,276
31,892
kWh
$700
-
kW-mo/yr
-
07 2.7142: Utilize higher efficiency lamps and/or ballasts $1,479 $1,875 $954
23,854
kWh
$525
-
kW-mo/yr
-
08 2.7135: Install occupancy sensors $1,242 $1,042 $1,242
31,049
kWh
- -
09 2.3132: Recharge batteries on during off-peak demand periods $1,158 $1,827 - $1,158
-
kW-mo/yr
-
10 2.7228: Avoid introducing hot, humid, or dirty air into hvac system $744 $965 $488
12,210
kWh
$256
-
kW-mo/yr
-
11 2.2511: Insulate bare equipment $688 $682 $271
6,783
kWh
$417
-
kW-mo/yr
-
TOTAL RECOMMENDED $34,220 $36,000 $14,923
373,113
kWh
$15,239
-
kW-mo/yr
$4,058
-
Tgal
TOTAL IMPLEMENTED - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Water Disposal Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs