Assessment Year | 2021 |
---|---|
Principal Product | pet bottles, jars |
NAICS | 326160: Plastics Bottle Manufacturing |
SIC | 3085: Plastics Bottles |
Sales Range | $10 M to 50M |
# of Employees | 72 |
Plant Area |
45,000
ft2
|
Annual Production | 70,000,000
pieces
|
Production Hrs. Annual | 7,344
hrs
|
Location (State) | Florida |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $151,367 | 3,777,861 |
kWh
|
$0.040 | |
Electricity Demand | $117,722 | 8,745 |
kW-mo/yr
|
$13.46 | |
Electricity Fees | $37,460 | - |
|
- | |
Waste Disposal Costs | |||||
Water Usage | $11,268 | 2,126 |
Tgal
|
$5.30 | |
Water Disposal | $17,943 | 2,126 |
Tgal
|
$8.44 | |
TOTAL YEARLY COSTS | $335,760 | ||||
RECOMMENDED SAVINGS* | $34,220 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Water Disposal Savings |
---|---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $9,975 | $1,980 |
$3,190
79,762
kWh
|
$6,785
-
kW-mo/yr
|
- | |
02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $7,215 | $2,100 |
$4,415
110,384
kWh
|
$2,800
-
kW-mo/yr
|
- | |
03 | 3.4116: Meter recycled water (to reduce sewer charges) | $4,058 | $1,306 | - | - |
$4,058
-
Tgal
|
|
04 | 2.7252: Utilize an evaporative air pre-cooler or other heat exchanger in ac system | $3,560 | $17,760 |
$2,295
57,370
kWh
|
$1,265
-
kW-mo/yr
|
- | |
05 | 2.7447: Install vinyl strip / high speed / air curtain doors | $2,125 | $2,048 |
$792
19,809
kWh
|
$1,333
-
kW-mo/yr
|
- | |
06 | 2.7229: Air condition only space necessary | $1,976 | $4,415 |
$1,276
31,892
kWh
|
$700
-
kW-mo/yr
|
- | |
07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,479 | $1,875 |
$954
23,854
kWh
|
$525
-
kW-mo/yr
|
- | |
08 | 2.7135: Install occupancy sensors | $1,242 | $1,042 |
$1,242
31,049
kWh
|
- | - | |
09 | 2.3132: Recharge batteries on during off-peak demand periods | $1,158 | $1,827 | - |
$1,158
-
kW-mo/yr
|
- | |
10 | 2.7228: Avoid introducing hot, humid, or dirty air into hvac system | $744 | $965 |
$488
12,210
kWh
|
$256
-
kW-mo/yr
|
- | |
11 | 2.2511: Insulate bare equipment | $688 | $682 |
$271
6,783
kWh
|
$417
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $34,220 | $36,000 |
$14,923
373,113
kWh
|
$15,239
-
kW-mo/yr
|
$4,058
-
Tgal
|
||
TOTAL IMPLEMENTED | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Water Disposal Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs