ITAC Assessment: MI0376
ITAC logo
ITAC Assessment: MI0376
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2020
Principal Product Private Jets
NAICS 336411: Aircraft Manufacturing
SIC 3721: Aircraft
Sales Range $50
M
to 100
M
# of Employees 400
Plant Area 300,000
ft2
Annual Production 19
pieces
Production Hrs. Annual 6,240
hrs
Location (State) Florida

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $465,291 12,835,480
kWh
Electricity Demand $408,138 30,085
kW-mo/yr
Electricity Fees $117,521 -
Fuel Oil #2 $2,050 123
MMBtu
TOTAL YEARLY COSTS $993,000
RECOMMENDED SAVINGS* $536,985 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $4,838

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Fuel Oil #2 Savings Administrative Changes Savings
01 2.8114: Change rate schedules or other changes in utility service $234,414 $800 - - $(-48,990.0)
-
MMBtu
$283,404
02 2.7232: Replace existing hvac unit with high efficiency model $205,000 $1,013,224 $27,009
750,245
kWh
$171,691
-
kW-mo/yr
- $6,300
03 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $55,477 $1,980 $36,552
1,015,322
kWh
$18,925
-
kW-mo/yr
- -
04 2.7221: Lower temperature during the winter season and vice-versa $25,854 $580 $17,036
473,212
kWh
$8,818
-
kW-mo/yr
- -
05 2.7144: Install spectral reflectors / delamp $6,695 $5,875 $3,317
92,151
kWh
$3,378
-
kW-mo/yr
- -
06 2.7142: Utilize higher efficiency lamps and/or ballasts $4,838 $9,120 $2,396
66,553
kWh
$2,442
-
kW-mo/yr
- -
07 2.7442: Keep doors and windows shut when not on use $3,944 $440 $2,601
72,241
kWh
$1,343
-
kW-mo/yr
- -
08 2.4111: Utilize energy-efficient belts and other improved mechanisms $763 $289 $424
11,766
kWh
$339
-
kW-mo/yr
- -
TOTAL RECOMMENDED $536,985 $1,032,308 $89,335
2,481,490
kWh
$206,936
-
kW-mo/yr
$(-48,990.0)
-
MMBtu
$289,704
TOTAL IMPLEMENTED $4,838 $9,120 $2,396
66,553
kWh
$2,442
-
kW-mo/yr
- -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Fuel Oil #2 Savings Administrative Changes Savings