Assessment Year | 2020 |
---|---|
Principal Product | Private Jets |
NAICS | 336411: Aircraft Manufacturing |
SIC | 3721: Aircraft |
Sales Range | $50 M to 100M |
# of Employees | 400 |
Plant Area |
300,000
ft2
|
Annual Production | 19
pieces
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | Florida |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $465,291 | 12,835,480 |
kWh
|
$0.036 |
Electricity Demand | $408,138 | 30,085 |
kW-mo/yr
|
$13.57 |
Electricity Fees | $117,521 | - |
|
- |
Fuel Oil #2 | $2,050 | 123 |
MMBtu
|
$16.67 |
TOTAL YEARLY COSTS | $993,000 | |||
RECOMMENDED SAVINGS* | $536,985 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $4,838 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Fuel Oil #2 Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.8114: Change rate schedules or other changes in utility service | $234,414 | $800 | - | - |
$(-48,990.0)
-
MMBtu
|
$283,404 | |
02 | 2.7232: Replace existing hvac unit with high efficiency model | $205,000 | $1,013,224 |
$27,009
750,245
kWh
|
$171,691
-
kW-mo/yr
|
- | $6,300 | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $55,477 | $1,980 |
$36,552
1,015,322
kWh
|
$18,925
-
kW-mo/yr
|
- | - | |
04 | 2.7221: Lower temperature during the winter season and vice-versa | $25,854 | $580 |
$17,036
473,212
kWh
|
$8,818
-
kW-mo/yr
|
- | - | |
05 | 2.7144: Install spectral reflectors / delamp | $6,695 | $5,875 |
$3,317
92,151
kWh
|
$3,378
-
kW-mo/yr
|
- | - | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,838 | $9,120 |
$2,396
66,553
kWh
|
$2,442
-
kW-mo/yr
|
- | - | |
07 | 2.7442: Keep doors and windows shut when not on use | $3,944 | $440 |
$2,601
72,241
kWh
|
$1,343
-
kW-mo/yr
|
- | - | |
08 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $763 | $289 |
$424
11,766
kWh
|
$339
-
kW-mo/yr
|
- | - | |
TOTAL RECOMMENDED | $536,985 | $1,032,308 |
$89,335
2,481,490
kWh
|
$206,936
-
kW-mo/yr
|
$(-48,990.0)
-
MMBtu
|
$289,704 | ||
TOTAL IMPLEMENTED | $4,838 | $9,120 |
$2,396
66,553
kWh
|
$2,442
-
kW-mo/yr
|
- | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Fuel Oil #2 Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs