ITAC Assessment: MI0374
ITAC logo
ITAC Assessment: MI0374
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2020
Principal Product Refrigeration Equipment
NAICS 333415: Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipmen
SIC 3585: Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment
Sales Range $50
M
to 100
M
# of Employees 287
Plant Area 150,000
ft2
Annual Production 3,102
pieces
Production Hrs. Annual 2,625
hrs
Location (State) Florida

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $188,577 1,534,790
kWh
Electricity Fees $19,323 -
TOTAL YEARLY COSTS $207,900
RECOMMENDED SAVINGS* $44,595 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Fees Savings One-time Revenue or Avoided Cost Savings
01 2.8114: Change rate schedules or other changes in utility service $23,161 $320 - $23,161 -
02 2.7442: Keep doors and windows shut when not on use $7,650 $4,760 $7,650
62,194
kWh
- -
03 2.7221: Lower temperature during the winter season and vice-versa $4,237 $480 $4,237
34,450
kWh
- -
04 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $3,360 $1,980 $3,360
27,321
kWh
- -
05 2.7135: Install occupancy sensors $2,170 $1,356 $2,170
17,640
kWh
- -
06 4.322: Eliminate old stock and modify inventory control $2,000 $160 - - $2,000
07 2.7111: Reduce illumination to minimum necessary levels $1,446 $1,238 $1,446
11,760
kWh
- -
08 2.4227: Use compressor air filters $571 $562 $571
4,644
kWh
- -
TOTAL RECOMMENDED $44,595 $10,856 $19,434
158,009
kWh
$23,161 $2,000
TOTAL IMPLEMENTED - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Fees Savings One-time Revenue or Avoided Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs