Assessment Year | 2020 |
---|---|
Principal Product | Refrigeration Equipment |
NAICS | 333415: Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipmen |
SIC | 3585: Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment |
Sales Range | $50 M to 100M |
# of Employees | 287 |
Plant Area |
150,000
ft2
|
Annual Production | 3,102
pieces
|
Production Hrs. Annual | 2,625
hrs
|
Location (State) | Florida |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $188,577 | 1,534,790 |
kWh
|
$0.12 |
Electricity Fees | $19,323 | - |
|
- |
TOTAL YEARLY COSTS | $207,900 | |||
RECOMMENDED SAVINGS* | $44,595 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Fees Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|
01 | 2.8114: Change rate schedules or other changes in utility service | $23,161 | $320 | - | $23,161 | - | |
02 | 2.7442: Keep doors and windows shut when not on use | $7,650 | $4,760 |
$7,650
62,194
kWh
|
- | - | |
03 | 2.7221: Lower temperature during the winter season and vice-versa | $4,237 | $480 |
$4,237
34,450
kWh
|
- | - | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,360 | $1,980 |
$3,360
27,321
kWh
|
- | - | |
05 | 2.7135: Install occupancy sensors | $2,170 | $1,356 |
$2,170
17,640
kWh
|
- | - | |
06 | 4.322: Eliminate old stock and modify inventory control | $2,000 | $160 | - | - | $2,000 | |
07 | 2.7111: Reduce illumination to minimum necessary levels | $1,446 | $1,238 |
$1,446
11,760
kWh
|
- | - | |
08 | 2.4227: Use compressor air filters | $571 | $562 |
$571
4,644
kWh
|
- | - | |
TOTAL RECOMMENDED | $44,595 | $10,856 |
$19,434
158,009
kWh
|
$23,161 | $2,000 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Fees Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs