ITAC Assessment: MI0307
ITAC logo
ITAC Assessment: MI0307
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2017
Principal Product Silk Screen Printed Shirts
NAICS 313310: Textile and Fabric Finishing Mills
SIC 2261: Finishers of Broadwoven Fabrics of Cotton
Sales Range $10
M
to 50
M
# of Employees 100
Plant Area 220,000
ft2
Annual Production 2,820,000
units
Production Hrs. Annual 3,250
hrs
Location (State) Florida

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $44,061 924,720
kWh
Electricity Demand $44,741 4,332
kW-mo/yr
Electricity Fees $13,608 -
Natural Gas $7,582 674
MMBtu
TOTAL YEARLY COSTS $109,992
RECOMMENDED SAVINGS* $50,609 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $30,380

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Administrative Changes Savings
01 2.6218: Turn off equipment when not in use $12,345 $3,600 $12,345
257,192
kWh
- - -
02 2.2628: Utilize a less expensive cooling method $10,877 $56,000 $2,334
48,620
kWh
$744
-
kW-mo/yr
- $7,800
03 2.7142: Utilize higher efficiency lamps and/or ballasts $8,777 $23,135 $4,846
100,961
kWh
$3,931
-
kW-mo/yr
- -
04 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $4,347 $1,660 $1,486
30,951
kWh
$2,861
-
kW-mo/yr
- -
05 2.7135: Install occupancy sensors $2,611 $6,150 $2,611
54,403
kWh
- - -
06 2.6231: Utilize controls to operate equipment only when needed $2,403 $842 $2,403
50,052
kWh
- - -
07 2.7425: Clean or color roof to reduce solar load $2,323 $1,720 $1,084
22,594
kWh
$1,239
-
kW-mo/yr
- -
08 2.7233: Use properly designed and sized hvac equipment $1,536 $3,370 $856
17,836
kWh
- - $680
09 2.2437: Recover waste heat from equipment $1,516 $8,584 - - $1,516
-
MMBtu
-
10 2.5193: Convert from batch to continuous operation $1,137 $800 - - $1,137
-
MMBtu
-
11 2.4239: Eliminate or reduce compressed air usage $845 $1,450 $473
9,871
kWh
$372
-
kW-mo/yr
- -
12 2.7134: Use photocell controls $840 $600 $840
17,494
kWh
- - -
13 2.7221: Lower temperature during the winter season and vice-versa $692 $240 $692
14,420
kWh
- - -
14 2.7221: Lower temperature during the winter season and vice-versa $359 $40 $277
5,779
kWh
$82
-
kW-mo/yr
- -
TOTAL RECOMMENDED $50,609 $108,191 $30,248
630,173
kWh
$9,229
-
kW-mo/yr
$2,653
-
MMBtu
$8,480
TOTAL IMPLEMENTED $30,380 $33,765 $21,587
449,733
kWh
$8,113
-
kW-mo/yr
- $680
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Administrative Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs