Assessment Year | 2017 |
---|---|
Principal Product | Silk Screen Printed Shirts |
NAICS | 313310: Textile and Fabric Finishing Mills |
SIC | 2261: Finishers of Broadwoven Fabrics of Cotton |
Sales Range | $10 M to 50M |
# of Employees | 100 |
Plant Area |
220,000
ft2
|
Annual Production | 2,820,000
units
|
Production Hrs. Annual | 3,250
hrs
|
Location (State) | Florida |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $44,061 | 924,720 |
kWh
|
$0.048 |
Electricity Demand | $44,741 | 4,332 |
kW-mo/yr
|
$10.33 |
Electricity Fees | $13,608 | - |
|
- |
Natural Gas | $7,582 | 674 |
MMBtu
|
$11.25 |
TOTAL YEARLY COSTS | $109,992 | |||
RECOMMENDED SAVINGS* | $50,609 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $30,380 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.6218: Turn off equipment when not in use | $12,345 | $3,600 |
$12,345
257,192
kWh
|
- | - | - | |
02 | 2.2628: Utilize a less expensive cooling method | $10,877 | $56,000 |
$2,334
48,620
kWh
|
$744
-
kW-mo/yr
|
- | $7,800 | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $8,777 | $23,135 |
$4,846
100,961
kWh
|
$3,931
-
kW-mo/yr
|
- | - | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $4,347 | $1,660 |
$1,486
30,951
kWh
|
$2,861
-
kW-mo/yr
|
- | - | |
05 | 2.7135: Install occupancy sensors | $2,611 | $6,150 |
$2,611
54,403
kWh
|
- | - | - | |
06 | 2.6231: Utilize controls to operate equipment only when needed | $2,403 | $842 |
$2,403
50,052
kWh
|
- | - | - | |
07 | 2.7425: Clean or color roof to reduce solar load | $2,323 | $1,720 |
$1,084
22,594
kWh
|
$1,239
-
kW-mo/yr
|
- | - | |
08 | 2.7233: Use properly designed and sized hvac equipment | $1,536 | $3,370 |
$856
17,836
kWh
|
- | - | $680 | |
09 | 2.2437: Recover waste heat from equipment | $1,516 | $8,584 | - | - |
$1,516
-
MMBtu
|
- | |
10 | 2.5193: Convert from batch to continuous operation | $1,137 | $800 | - | - |
$1,137
-
MMBtu
|
- | |
11 | 2.4239: Eliminate or reduce compressed air usage | $845 | $1,450 |
$473
9,871
kWh
|
$372
-
kW-mo/yr
|
- | - | |
12 | 2.7134: Use photocell controls | $840 | $600 |
$840
17,494
kWh
|
- | - | - | |
13 | 2.7221: Lower temperature during the winter season and vice-versa | $692 | $240 |
$692
14,420
kWh
|
- | - | - | |
14 | 2.7221: Lower temperature during the winter season and vice-versa | $359 | $40 |
$277
5,779
kWh
|
$82
-
kW-mo/yr
|
- | - | |
TOTAL RECOMMENDED | $50,609 | $108,191 |
$30,248
630,173
kWh
|
$9,229
-
kW-mo/yr
|
$2,653
-
MMBtu
|
$8,480 | ||
TOTAL IMPLEMENTED | $30,380 | $33,765 |
$21,587
449,733
kWh
|
$8,113
-
kW-mo/yr
|
- | $680 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs