Assessment Year | 2016 |
---|---|
Principal Product | HVAC Vents |
NAICS | 333415: Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipmen |
SIC | 3585: Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment |
Sales Range | $10 M to 50M |
# of Employees | 127 |
Plant Area |
240,000
ft2
|
Annual Production | 120,000
units
|
Production Hrs. Annual | 2,210
hrs
|
Location (State) | Florida |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $157,302 | 2,355,600 |
kWh
|
$0.067 |
Electricity Demand | $52,098 | 9,059 |
kW-mo/yr
|
$5.75 |
Electricity Fees | $32,763 | - |
|
- |
TOTAL YEARLY COSTS | $242,164 | |||
RECOMMENDED SAVINGS* | $63,548 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $15,540 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.6231: Utilize controls to operate equipment only when needed | $21,479 | $10,875 |
$21,479
320,580
kWh
|
- | |
02 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $15,453 | $13,550 |
$11,617
173,385
kWh
|
$3,836
-
kW-mo/yr
|
|
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $14,922 | $1,700 |
$10,961
163,595
kWh
|
$3,961
-
kW-mo/yr
|
|
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,269 | $19,877 |
$2,912
43,462
kWh
|
$1,357
-
kW-mo/yr
|
|
05 | 2.6231: Utilize controls to operate equipment only when needed | $3,903 | $1,473 |
$3,903
58,250
kWh
|
- | |
06 | 2.7135: Install occupancy sensors | $1,359 | $2,950 |
$1,359
20,282
kWh
|
- | |
07 | 2.4323: Use optimum size and capacity equipment | $1,203 | $2,914 |
$886
13,218
kWh
|
$317
-
kW-mo/yr
|
|
08 | 2.7447: Install vinyl strip / high speed / air curtain doors | $380 | $780 |
$340
5,075
kWh
|
$40
-
kW-mo/yr
|
|
09 | 2.7111: Reduce illumination to minimum necessary levels | $342 | $760 |
$233
3,482
kWh
|
$109
-
kW-mo/yr
|
|
10 | 2.7444: Close holes and openings in building such as broken windows | $203 | $50 |
$180
2,683
kWh
|
$23
-
kW-mo/yr
|
|
11 | 2.7444: Close holes and openings in building such as broken windows | $35 | $19 |
$29
434
kWh
|
$6
-
kW-mo/yr
|
|
TOTAL RECOMMENDED | $63,548 | $54,948 |
$53,899
804,446
kWh
|
$9,649
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | $15,540 | $2,549 |
$11,510
171,787
kWh
|
$4,030
-
kW-mo/yr
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs