ITAC Assessment: MI0299
ITAC logo
ITAC Assessment: MI0299
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2016
Principal Product Tobacco Products
NAICS 312230: Tobacco Manufacturing
SIC 2111: Cigarettes
Sales Range $10
M
to 50
M
# of Employees 100
Plant Area 100,000
ft2
Annual Production 1,800,000
units
Production Hrs. Annual 4,420
hrs
Location (State) Florida

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $118,645 2,514,000
kWh
Electricity Demand $76,923 6,441
kW-mo/yr
Electricity Fees $40,875 -
TOTAL YEARLY COSTS $236,444
RECOMMENDED SAVINGS* $85,729 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $25,613

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Administrative Changes Savings
01 2.2628: Utilize a less expensive cooling method $39,996 $70,000 $22,870
486,591
kWh
$8,026
-
kW-mo/yr
$9,100
02 2.7293: Install dry sprinkler system or other method to reduce heating requirements $10,788 $66,330 $7,993
170,072
kWh
$2,795
-
kW-mo/yr
-
03 2.7221: Lower temperature during the winter season and vice-versa $8,688 $320 $5,141
109,389
kWh
$3,547
-
kW-mo/yr
-
04 2.7142: Utilize higher efficiency lamps and/or ballasts $7,678 $27,288 $4,329
92,104
kWh
$3,349
-
kW-mo/yr
-
05 2.7447: Install vinyl strip / high speed / air curtain doors $4,745 $5,246 $2,808
59,745
kWh
$1,937
-
kW-mo/yr
-
06 2.4221: Install compressor air intakes in coolest locations $3,417 $650 $2,020
42,984
kWh
$1,397
-
kW-mo/yr
-
07 2.7142: Utilize higher efficiency lamps and/or ballasts $3,054 $9,821 $3,054
64,987
kWh
- -
08 2.7447: Install vinyl strip / high speed / air curtain doors $2,889 $2,360 $1,707
36,312
kWh
$1,182
-
kW-mo/yr
-
09 2.4239: Eliminate or reduce compressed air usage $1,698 $6,750 $981
20,863
kWh
$717
-
kW-mo/yr
-
10 2.7447: Install vinyl strip / high speed / air curtain doors $1,162 $1,885 $863
18,363
kWh
$299
-
kW-mo/yr
-
11 2.7134: Use photocell controls $776 $480 $776
16,511
kWh
- -
12 2.7135: Install occupancy sensors $570 $795 $570
12,133
kWh
- -
13 2.7447: Install vinyl strip / high speed / air curtain doors $213 $352 $121
2,580
kWh
$92
-
kW-mo/yr
-
14 2.7495: Install replacement doors $55 $480 $55
1,167
kWh
- -
TOTAL RECOMMENDED $85,729 $192,757 $53,288
1,133,801
kWh
$23,341
-
kW-mo/yr
$9,100
TOTAL IMPLEMENTED $25,613 $42,071 $16,929
360,218
kWh
$8,684
-
kW-mo/yr
-
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Administrative Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs